In vivo observation of subendocardial microvessels of the beating porcine heart using a needle-probe videomicroscope with a CCD camera.
نویسندگان
چکیده
We developed a portable needle-probe videomicroscope with a charge-coupled device (CCD) camera to visualize the subendocardial microcirculation. In 12 open-chest anesthetized pigs, the sheathed needle probe with a doughnut-shaped balloon and a microtube for flushing away the intervening blood was introduced into the left ventricle through an incision in the left atrial appendage via the mitral valve. Images of the subendocardial microcirculation of the beating heart magnified by 200 or 400 on a 15-in. monitor were obtained. The phasic diameter change in subendocardial arterioles during cardiac cycle was from 114 +/- 46 microns (mean +/- SD) in end diastole to 84 +/- 26 microns in end systole (p < 0.001, n = 13, ratio of change = 24%) and that in venules from 134 +/- 60 microns to 109 +/- 45 microns (p < 0.001, n = 15, ratio of change = 17%). In contrast, the diameter of subepicardial arterioles was almost unchanged (2% decrease, n = 5, p < 0.01), and the venular diameter increased by 19% (n = 8, p < 0.001) from end diastole to end systole. Partial kinking and/or pinching of vessels was observed in some segments of subendocardial arterioles and venules. The percentage of systolic decrease in the diameter from diastole in the larger (> 100 microns) subendocardial arterioles and venules was greater than smaller (50-100 microns) vessels (both p < 0.05). In conclusion, using a newly developed microscope system, we were able to observe the subendocardial vessels in diastole and systole.(ABSTRACT TRUNCATED AT 250 WORDS)
منابع مشابه
In Vivo Observation of Subendocardial Microvessels of the Beating Porcine Heart Using a Needle
We developed a portable needle-probe videomicroscope with a charge-coupled device (CCD) camera to visualize the subendocardial microcirculation. In 12 open-chest anesthetized pigs, the sheathed needle probe with a doughnut-shaped balloon and a microtube for flushing away the intervening blood was introduced into the left ventricle through an incision in the left atrial appendage via the mitral ...
متن کاملDiameters of subendocardial arterioles and venules during prolonged diastole in canine left ventricles.
Using a needle-probe videomicroscope with a charge-coupled device (CCD) camera, we measured the diameter of subendocardial arterioles and venules during prolonged diastole beyond the time point at which coronary blood flow reached zero. In seven open-chest heart-blocked dogs, a sheathed needle probe with a doughnut-shaped balloon was introduced from the left atrial appendage and advanced into t...
متن کاملDynamics of flow velocities in endocardial and epicardial coronary arterioles.
The subendocardium is the most vulnerable area of the left ventricle to the effects of hypoperfusion and ischemia. Despite this well-acknowledged observation, the mechanisms underlying this susceptibility are not elucidated, although numerous explanations including differences in transmural distribution of hemodynamics, metabolism, and wall stresses have been proposed. Our goal was to make dyna...
متن کاملVenules During Prolonged Diastole in Canine Left Ventricles
Using a needle-probe videomicroscope with a charge-coupled device (CCD) camera, we measured the diameter of subendocardial arterioles and venules during prolonged diastole beyond the time point at which coronary blood flow reached zero. In seven open-chest heart-blocked dogs, a sheathed needle probe with a doughnut-shaped balloon was introduced from the left atrial appendage and advanced into t...
متن کاملUse of Carbon dioxide versus air blower in on-pump beating-heart coronary artery bypass surgery
Introduction: The use of carbon dioxide blower has been recognized as the standard of care in patients undergoing beating coronary artery bypass grafting (CABG) due to higher solubility and lower risk of embolization. On the other hand, the compressed air blower has gone out of use since air can be easily trapped and is less soluble which can cause coronary embolism. The prese...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation research
دوره 72 5 شماره
صفحات -
تاریخ انتشار 1993