First clinical results with a real time, electronic imager as an aid to colonoscopy.
نویسندگان
چکیده
The early clinical results are described of a real time, electromagnetic imaging system as an aid to colonoscopy. After gaining experience with the use of the system, one experienced endoscopist was randomised to perform consecutive colonoscopies either with (n = 29) or without (n = 26) the imager view. All procedures were recorded on computer disk and replayed for retrospective analysis. Total colonoscopy was achieved in all patients except one (imager view not available). Comparing intubation time and duration of loop formation per patient, there was no significant difference between the two study groups. The number of attempts taken to straighten the colonoscope pre patient, however, was less when the endoscopist was able to see the imager view, p = 0.03. Hand pressure was also more effective when the endoscopist and endoscopy assistant could see the imager display, p = 0.02. Preliminary experience suggests that real time, electronic imaging of colonoscopy is safe, effective, and will improve the accuracy of the procedure.
منابع مشابه
Effect of Polyethylene Glycol and Senna Bowel Preparation in Dogs on Some Hematological and Serum Biochemical Parameters
Background: Colonoscopy is the preferred procedure for diagnosis of large-bowel diseases in dogs. Polyethylene glycol (PEG) is the most commonly used laxative for colonic cleansing. Senna has been used in traditional medicine as a laxative and an aid to treat constipation. OBJECTIVES: The aim of this study was to evaluate the safety of senna as an alternative or adjunct to polyethylene glycol s...
متن کاملReal Time Electronic Formative Assessment in Medical Education and its Impact on Learning
Introduction: The aim of this study was to investigate the learning environment based on real time electronic formative assessment in medical education and its impact on learning. Methods: This randomized clinical trial was conducted on 323 students studying at the Medical School of Mashhad University of Medical Sciences, Mashhad, Iran, during the first semester of the academic year of 2017-201...
متن کاملReal Time Electronic Formative Assessment in Medical Education and Its Impact on Motivational Beliefs and Self-regulation Strategies
Background and Objectives: The aim of this study was to investigate the effect of real-time electronic formative assessment-based medical education on learners’ motivational beliefs and self-regulation strategies. Methods: This randomized clinical trial was conducted on 323 students studying at the Medical School of Mashhad University of Medical Sciences, Mashhad, Iran, during the first semeste...
متن کاملComparison of the analgesic effect of intravenous paracetamol/midazolam and fentanyl in preparation
Background: Although some patients can tolerate colonoscopy procedure using fentanyl/ midazolam without any sedation and analgesic requirements but some patients may require additional sedation with benzodiazepines. We performed the present study to compare the effect of paracetamol/midazolam with fentanyl/ midazolam. Methods: In a clinical trial, 96 patients aged 18 to 75 years old, ...
متن کاملIn vivo dose verification using using an amorphous silicon flat panel-type imager (a-Si EPIDs)
Introduction: Electronic portal imaging devices (EPIDs) could be used to dose verification of radiotherapy treatment plans. In vivo dose verification is performed to reduce differences found between dose delivered to the patient and the prescribed dose. The aim of this study was to perform a fast and efficient technique for the verification of delivered dose to the patient usin...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Gut
دوره 36 6 شماره
صفحات -
تاریخ انتشار 1995