Obesity and smoking: are they modulators of cough intravesical peak pressure in stress urinary incontinence?

نویسندگان

  • Paulo Emilio Fuganti
  • John Michael Gowdy
  • Nilton Cesar Santiago
چکیده

PURPOSE SUI (Stress Urinary Incontinence) results from sudden increases in intravesical peak pressures exceeding urethral resistance leading to involuntary urine loss. Obesity and smoking are well established reversible risk factors for SUI and may alter intravesical peak pressures. BMI, smoking status, and other clinical factors were studied to determine their relationship to CIPP (maximal Intravesical Peak Pressures generated by Cough) in SUI complaining women. MATERIALS AND METHODS Three hundred nineteen women complaining of SUI were evaluated with medical history and urodynamics. Age, parity, comorbidities, previous surgery, BMI and history of smoking were obtained. The maximal intravesical peak pressures generated by cough (CIPP) and cough leak point pressure (CLPP) were acquired. Univariate and multivariate analysis were conducted. RESULTS Current smokers and former smokers had similar CIPP (170cmH₂O and 170cmH₂O; p = 0.5, respectively); Those individuals who had never smoked had significantly lower CIPP (140cmH₂O; p = 0.000 and p = 0.009 respectively). BMI was directly related to CIPP (r = 0.41; p = 0.000). Vaginal deliveries (r = -0.15, p = 0.08) and diabetes (r = 0.15, p = 0.016) were also directly related to CIPP on univariate analysis. Only smoking status (p = 0.000) and BMI (p = 0.000) were independently significantly related to CIPP on multivariate analysis. CONCLUSIONS Obesity and smoking showed increased CIPP (maximal Intravesical Peak Pressures generated by Cough). While reduced BMI is related to lower CIPP, smoking cessation does not appear to diminish CIPP. These findings suggest that weight loss may reduce incontinence by CIPP modulation. However, the benefits of smoking cessation without additional lifestyle modification, may have no benefit to improve urinary incontinence.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of Methods for Urinary Detection in Women with Stress Urinary Incontinence

PURPOSE We assessed the accuracy of urinary detection by visualization compared with a method using the urethral channel of a transurethral, three-channel urodynamic catheter. MATERIALS AND METHODS This was a case series of 52 patients presenting with stress urinary incontinence over 2 years. Patients underwent video-urodynamic studies in both the supine and the erect positions by use of two ...

متن کامل

Pathophysiology of urinary incontinence and pelvic organ prolapse.

Stress urinary incontinence is the complaint of involuntary leakage of urine on effort or exertion, or on sneezing or coughing. In urodynamic terms, stress continence is maintained when the maximum urethral pressure exceeds the intravesical pressure. In the McGuire classification system, type 1 and 2 stress incontinence occur because of urethral hypermobility and type 3 because of intrinsic sph...

متن کامل

Diagnostic categories of incontinence and the role of urodynamic testing.

rinary incontinence is the result of an imbalance between the maximum intravesical pressure and the maximum urethral pressure U at any given time except during normal voiding. Any combination that brings about an excess of intravesical pressure over the maximum urethral pressure will result in urine loss. Such combinations are outlined in Table 1. This simplified table does not necessarily indi...

متن کامل

Re: A Randomized Controlled Clinical Trial of an Intravesical Pressure Attenuation Balloon System for the Treatment of Stress Urinary Incontinence in Females.

AIMS Evaluate the efficacy, safety, and tolerability of a novel pressure-attenuation balloon for the treatment of female stress urinary incontinence (SUI) using a prospective, randomized, single-blind, multi-center design, evaluated at 3 months. METHODS Sixty-three females with SUI were randomized 2:1 to treatment with a balloon (N = 41) or sham procedure (N = 22). The sham (control) entailed...

متن کامل

Valsalva Leak Point Pressure Measurement in Women with Stress Urinary Incontinence: At What Bladder Volume?

Submit Manuscript | http://medcraveonline.com Abbreviations: LPP: Leak Point Pressure; DLPP: Detrusor Leak Point Pressure; ALPP: Abdominal Leak Point Pressure; SLPP: Stress Leak Point Pressure; VLPP: Valsalva Leak Point Pressure; CLPP: Cough Leak Point Pressure; SUI: Stress Urinary Incontinence; UDS: Urodynamic Study; ISD: Intrinsic Sphincter Dysfunction; IUS: Internal Urethral Sphincter, EUS: ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International braz j urol : official journal of the Brazilian Society of Urology

دوره 37 4  شماره 

صفحات  -

تاریخ انتشار 2011