In vivo tibia lead measurements as an index of cumulative exposure in occupationally exposed subjects.

نویسندگان

  • L J Somervaille
  • D R Chettle
  • M C Scott
  • D R Tennant
  • M J McKiernan
  • A Skilbeck
  • W N Trethowan
چکیده

In vivo tibia lead measurements of 20 non-occupationally exposed and 190 occupationally exposed people drawn from three factories were made using a non-invasive x ray fluorescence technique in which characteristic x rays from lead are excited by gamma rays from a cadmium-109 source. The maximum skin dose to a small region of the shin was 0.45 mSv. The relation between tibia lead and blood lead was weak in workers from one factory (r = 0.11, p greater than 0.6) and among the non-occupationally exposed subjects (r = 0.07, p greater than 0.7); however, a stronger relation was observed in the other two factories (r = 0.45, p less than 0.0001 and r = 0.53, p less than 0.0001). Correlation coefficients between tibia lead and duration of employment were consistently higher at all three factories respectively (r = 0.86, p less than 0.0001; r = 0.61, p less than 0.0001; r = 0.80, p less than 0.0001). A strong relation was observed between tibia lead and a simple, time integrated, blood lead index among workers from the two factories from which blood lead histories were available. The regression equation from two groups of workers (n = 88, 79) did not significantly differ despite different exposure conditions. The correlation coefficient for the combined data set (n = 167) was 0.84 (p less than 0.0001). This shows clearly that tibia lead, measured in vivo by x-ray fluorescence, provides a good indicator of long term exposure to lead as assessed by a cumulative blood lead index.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An improved instrument for the in vivo detection of lead in bone.

An improved instrument for the fluorescence excitation measurement of concentrations of lead in bone has been developed. This is based on a large area high purity germanium detector and a point source of 109Cd. The source is positioned in a tungsten shield at the centre of the detector face such that 88keV photons cannot enter the detector directly. In vivo measurements are calibrated with plas...

متن کامل

Repeated measurements of tibia lead concentrations by in vivo x ray fluorescence in occupational exposure.

A group of workers occupationally exposed to lead have had measurements of their tibia lead concentrations made on two occasions separated by five years; on the second occasion calcaneus lead concentrations were also measured. The results serve to confirm the reliability of the measurement technique and to illustrate the improved precision achieved through technical improvements. More important...

متن کامل

109Cd K x ray fluorescence measurements of tibial lead content in young adults exposed to lead in early childhood.

OBJECTIVES Tibia lead measurements were performed in a population of 19-29 year old people who had been highly exposed to lead in childhood to find whether lead had persisted in the bone matrix until adulthood. METHODS (109)Cd K x ray fluorescence was used to measure the tibia lead concentrations of 262 exposed subjects and 268 age and sex matched controls. Questionnaire data allowed a years ...

متن کامل

Radioadaptive response in peripheral blood leukocytes of occupationally exposed medical staff with investigation of DNA damage by the use of neutral comet assay

Background: ˝Radioadaptive Response˝ is well-documented phenomenon appeared in low dose ionizing radiation received in vitro and in vivo. Occupational exposure has always been a great concern for radiation workers therefore this study was performed to study radioadaptive response in terms of residual DNA double strand breaks as an endpoint in peripheral blood leukocytes of occupationally expose...

متن کامل

Impact of Occupational Exposure on Lead Levels in Women

In 1994, 207 women participated in a study designed to examine the effects of occupational exposure and various lifestyle factors on bone and blood lead levels. In vivo measurements of Pb concentrations in tibia were performed by X-ray fluorescence. All 108 former smelter employees and 99 referents provided blood samples and answered a questionnaire on lifestyle characteristics and the relevant...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of industrial medicine

دوره 45 3  شماره 

صفحات  -

تاریخ انتشار 1988