Predictors of the accuracy of pulse-contour cardiac index and suggestion of a calibration-index: a prospective evaluation and validation study

نویسندگان

  • Wolfgang Huber
  • Jonas Koenig
  • Sebastian Mair
  • Tibor Schuster
  • Bernd Saugel
  • Florian Eyer
  • Veit Phillip
  • Caroline Schultheiss
  • Philipp Thies
  • Ulrich Mayr
  • Henrik Einwächter
  • Matthias Treiber
  • Josef Hoellthaler
  • Roland M Schmid
چکیده

BACKGROUND Cardiac Index (CI) is a key-parameter of hemodynamic monitoring. Indicator-dilution is considered as gold standard and can be obtained by pulmonary arterial catheter or transpulmonary thermodilution (TPTD; CItd). Furthermore, CI can be estimated by Pulse-Contour-Analysis (PCA) using arterial wave-form analysis (CIpc). Obviously, adjustment of CIpc to CItd initially improves the accuracy of CIpc. Despite uncertainty after which time accuracy of CIpc might be inappropriate, recalibration by TPTD is suggested after a maximum of 8 h. We hypothesized that accuracy of CIpc might not only depend on time to last TPTD, but also on changes of the arterial wave curve detectable by PCA itself. Therefore, we tried to prospectively characterize predictors of accuracy and precision of CIpc (primary outcome). In addition to "time to last TPTD" we evaluated potential predictors detectable solely by pulse-contour-analysis. Finally, the study aimed to develop a pulse-contour-derived "calibration-index" suggesting recalibration and to validate these results in an independent collective. METHODS In 28 intensive-care-patients with PiCCO-monitoring (Pulsion Medical-Systems, Germany) 56 datasets were recorded. CIpc-values at baseline and after intervals of 1 h, 2 h, 4 h, 6 h and 8 h were compared to CItd derived from immediately subsequent TPTD. Results from this evaluation-collective were validated in an independent validation-collective (49 patients, 67 datasets). RESULTS Mean bias values CItd-CIpc after different intervals ranged between -0.248 and 0.112 L/min/m(2). Percentage-error after different intervals to last TPTD ranged between 18.6% (evaluation, 2 h-interval) and 40.3% (validation, 6 h-interval). In the merged data, percentage-error was below 30% after 1 h, 2 h, 4 h and 8 h, and exceeded 30% only after 6 h. "Time to last calibration" was neither associated to accuracy nor to precision of CIpc in any uni- or multivariate analysis. By contrast, the height of CIpc and particularly changes in CIpc compared to last thermodilution-derived CItd(base) univariately and independently predicted the bias CItd-CIpc in both collectives. Relative changes of CIpc compared to CItd(base) exceeding thresholds derived from the evaluation-collective (-11.6% < CIpc-CItd(base)/CItd(base) < 7.4%) were confirmed as significant predictors of a bias |CItd-CIpc| ≥ 20% in the validation-collective. CONCLUSION Recalibration triggered by changes of CIpc compared to CItd(base) derived from last calibration should be preferred to fixed intervals.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The prospective validation of EuroSCORE II risk scoring system for patients underwent cardiac surgery: brief report

Background: Various prediction models have been developed aiming to estimate risk-adjusted mortality, morbidity and length of intensive care unit stay following cardiac surgeries. The European system for cardiac operative risk evaluation II (EuroSCORE II) is a prediction model which maps 18 predictors to a 30-day post-operative risk of death. The objective of this study was to evaluate the perf...

متن کامل

تاثیر نوع ابرهای پایین جو بر میزان دقت شبیه سازی رواناب در مدل SWAT

Introduction: Patterns of spatial and temporal rainfall impact on runoff and outlet hydrograph (Cordery, 1993; James, 1994). Results of different studies have clarified that simulation by using diverse rainfall data could increase the reliance of results. These were much more sensible in which areas encounter with data scarcity (Mello et al., 2008; Bekiaris et al., 2008). Rainfall properties in...

متن کامل

Relationship between some indices of cardiovascular functions and pulse pressure as a predictor index for heart diseases: a case-control study

Background: Pulse pressure has recently been considered as a predictor of coronary heart disease. The difference between systolic and diastolic blood pressure is called pulse pressure. Various factors including increased age, vascular stiffness, stenosis, and hypertension are associated with pulse pressure. The present study, therefore, aimed to investigate the relationship between some cardiov...

متن کامل

Developing and Validation of Post-Traumatic Growth Protocol for Iranian Veterans

Background and Aim: Post-traumatic growth is a new concept in psychology, which is called positive personal changes that occur after a personchr('39')s exposure to traumatic events. The purpose of this study is to Compilation and validates the post-traumatic growth protocol for veterans of war. Methods: This research was conducted in a cross-sectional descriptive study in 2018. The statistical ...

متن کامل

Smartphone-based application for training outpatient cardiac rehabilitation: Design and usability evaluation

Introduction: Due to the increasing trend of heart diseases and their complications, programs such as cardiac rehabilitation can reduce the complications and faster recovery of patients. Therefore, the aim of this study was to design and evaluate the usability of smartphone-based application for training outpatient cardiac rehabilitation. Materials and Methods: This applied-developmental study ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2015