Improvement of pressurised aerosol deposition with Nebuhaler spacer device.

نویسندگان

  • S P Newman
  • A B Millar
  • T R Lennard-Jones
  • F Morén
  • S W Clarke
چکیده

The effect on aerosol deposition from a pressurised metered dose inhaler of a 750 cm3 spacer device with a one way inhalation valve (Nebuhaler, Astra Pharmaceuticals) was assessed by means of an in vivo radiotracer technique. Nine patients with obstructive lung disease took part in the study. The pattern of deposition associated with use of a metered dose inhaler alone was compared with that achieved with the spacer used both for inhalation of single puffs of aerosol and for inhalation of four puffs actuated in rapid succession and then inhaled simultaneously. On each occasion there was a delay of 1 s between aerosol release and inhalation, simulating poor inhaler technique. With the metered dose inhaler alone, a mean (SEM) 8.7 (1.8)% of the dose reached the lungs and 80.9 (1.9)% was deposited in the oropharynx. With single puffs from the spacer 20.9 (1.6)% of the dose (p less than 0.01) reached the lungs, only 16.5 (2.3)% (p less than 0.01) was deposited in the oropharynx, and 55.8 (3.1)% was retained within the spacer itself. With four puffs from the spacer 15.2 (1.5)% reached the lungs (p = 0.02 compared with the metered dose inhaler alone, p less than 0.01 compared with single puffs from the spacer), 11.4 (1.2)% was deposited in the oropharynx, and 67.5 (1.8)% in the device itself. It is concluded that the spacer device gives lung deposition of metered dose aerosols comparable to or greater than a correctly used inhaler and oropharyngeal deposition is greatly reduced. The spacer should be used preferably for the inhalation of single puffs of aerosol but may also be used for the inhalation of up to four puffs actuated in rapid succession and then inhaled simultaneously.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A non-electrostatic spacer for aerosol delivery.

A pear shaped non-electrostatic spacer, composed of steel with a volume of 250 ml and equipped with a facemask containing integrated inlet and outlet valves for inspiration and expiration, was compared with three plastic spacers. The plastic spacers were primed with repeated puffs from a budesonide pressurised metered dose inhaler (p-MDI) to minimise the electrostatic charge on the plastic. The...

متن کامل

Factors affecting the efficiency of aerosol therapy with pressurised metered-dose inhalers through plastic spacers.

AIM The main objective of this study was to compare the in vitro delivery of salbutamol from a chlorofluorocarbon(CFC)-propelled pressurised metered-dose inhaler (pMDI) versus a newly developed hydrofluoroalkane(HFA)-propelled pMDI through various spacers. In addition, we aimed to study the effect on bronchodilator response when using an optimal pMDI/spacer combination for aerosol delivery comp...

متن کامل

The effects of static charge in spacer devices on glucocorticosteroid aerosol deposition in asthmatic patients.

Electrostatic charge in plastic spacer devices has been shown in vitro to reduce delivery of asthma medications intended for inhalation, but the effect of static charge on in vivo drug deposition is unknown. A six-way randomized crossover study was conducted in 10 mild asthmatic patients. Two plastic spacers (Nebuhaler and Volumatic) and one metal spacer (Nebuchamber) were tested. The spacers w...

متن کامل

Pressurised aerosol deposition in the human lung with and without an "open" spacer device.

A radiotracer technique has been used to assess aerosol delivery from a pressurised metered dose inhaler, used both with and without a 10 cm cylindrical spacer attachment (Syncroner), which has an open section in its upper surface. The radionuclide technetium-99m (99mTc) was added to sodium cromoglycate in a canister (Intal inhaler; 1 mg/puff); in vitro studies with a multistage liquid impinger...

متن کامل

Inhalational drug delivery from seven different spacer devices.

BACKGROUND A study was performed to determine in vitro the difference in drug output of seven currently available spacer devices when used with different inhaled medications. METHODS A glass multistage liquid impinger (MSLI) was used to determine the amount of disodium cromoglycate (DSCG, 5 mg), salbutamol (100 micrograms), or budesonide (200 micrograms) obtained in various particle size rang...

متن کامل