Modelling the immunosuppressive effect of liver SBRT by simulating the dose to circulating lymphocytes: an in-silico planning study

نویسندگان

  • L. Basler
  • N. Andratschke
  • S. Ehrbar
  • M. Guckenberger
  • S. Tanadini-Lang
چکیده

BACKGROUND Tumor immune-evasion and associated failure of immunotherapy can potentially be overcome by radiotherapy, which however also has detrimental effects on tumor-infiltrating and circulating lymphocytes (CL). We therefore established a model to simulate the radiation-dose delivered to CL. METHODS A MATLAB-model was established to quantify the CL-dose during SBRT of liver metastases by considering the factors: hepatic blood-flow, -velocity and transition-time of individual hepatic segments, as well as probability-based recirculation. The effects of intra-hepatic tumor-location and size, fractionation and treatment planning parameters (VMAT, 3DCRT, photon-energy, dose-rate and beam-on-time) were analyzed. A threshold dose ≥0.5Gy was considered inactivating CL and CL0.5 (%) is the proportion of inactivated CL. RESULTS Mean liver dose was mostly influenced by treatment-modality, whereas CL0.5 was mostly influenced by beam-on-time. 3DCRT and VMAT (10MV-FFF) resulted in lowest CL0.5 values of 16 and 19%. Metastasis location influenced CL0.5, with a mean of 19% for both apical and basal and 31% for the central location. PTV-volume significantly increased CL0.5 from 27 to 67% (10MV-FFF) and from 31 to 98% (6MV-FFF) for PTV-volumes ranging from 14cm3 to 268cm3. CONCLUSION A simulation-model was established, quantifying the strong effects of treatment-technique, tumor-location and tumor-volume on dose to CL with potential implications for immune-optimized treatment-planning in the future.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The significance of determining the therapeutic dose of cyclosporine-A in patients undergoing organ transplantation

Immunosuppressive drugs are now unavoidibly used after the transpantation of liver,heart and bone marrow, as well as in certain autoimmune diseases.among these agents,cyclosporine-A (CYA) is one of the most effective Immunosuppressants which is widely used.but as any Immunosuppressive agent,the use of CYA is not without harmful side effects.neurotoxin,nephrotoxic and hepatotoxic complications,m...

متن کامل

Inhibition of Immune System by an Immunosuppressive Factor from a Human Prostatic Carcinoma Cell Line (JCA-1)

Prostatic carcinoma is the most commonly diagnosed tumor among men over 40 which results in over 30,000 deaths each year in the United States. Previous studies indicated that tumor cell lines produce and release several growth regulatory factors into their condition media and so far a number of human tumor cell-derived suppressor factors have been isolated that affect normal immune functions. I...

متن کامل

The evaluation of lung doses for radiation pneumonia risk in stereotactic body radiotherapy: A comparison of intensity modulated radiotherapy, intensity modulated arc therapy, cyberknife and helical tomotherapy

Background: Radiation Pneumonia (RP) is one of the most extensive side effects in Stereotactic Body Radiotherapy (SBRT) of lung cancer. SBRT are performed by means of Intensity Modulated Radiotherapy (IMRT), Intensity Modulated Arc Therapy (IMAT), CyberKnife (CK) or Helical Tomotherapy (HT) treatment methods. In this study, we performed a plan study to determine the plan parameter such as the M...

متن کامل

Low Dose Psoralen Plus Ultraviolet A (PUVA) Is an Effective and Safe Method for the Treatment of Chronic Graft Versus Host Disease

Background: Chronic graft versus host disease (ch.GVHD) is the most frequent late complication after allogenic stem-cell transplantation. Systemic immunosuppressive agents are usually required to control the disease. Psoralen plus UVA (PUVA) has been used for the treatment of ch.GVHD with variable beneficial effects. The objective of this study was to assess the efficacy and safety of a r...

متن کامل

Dosimetric impact of different CT datasets for stereotactic treatment planning using 3D conformal radiotherapy or volumetric modulated arc therapy

BACKGROUND The purpose of this study was to assess the impact on dose to the planning target volume (PTV) and organs at risk (OAR) by using four differently generated CT datasets for dose calculation in stereotactic body radiotherapy (SBRT) of lung and liver tumors. Additionally, dose differences between 3D conformal radiotherapy and volumetric modulated arc therapy (VMAT) plans calculated on t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2018