Fixation of Periprosthetic Supracondylar Femur Fractures Above Total Knee Arthroplasty – The Indirect Reduction Technique with the Condylar Blade Plate and the Minimally Invasive Technique with the LISS

نویسندگان

  • K. Kolb
  • W. Kolb
چکیده

Supracondylar fractures of the femur after total knee arthroplasty are an uncommon but highly challenging injury (Streubel et al., 2010). The management of distal femoral fractures following a total knee replacement can be complex and requires the equipment, perioperative support and surgical skills of both trauma and revision arthroplasty services (Johnston et al., 2011, Nauth et al., 2011). The incidence of periprosthetic supracondylar femur fractures after total knee arthroplasties ranges from 0.3% to 2.5%. A patient with revision total knee arthroplasty has a significantly higher risk of supracondylar fracture above the prosthesis (2-4%) (Merkel & Johnson, 1986; Berry, 1999). Interprosthetic femoral fractures tend to occur more frequently in the supracondylar region above total knee arthroplasty components (Mamczak et al., 2010). Predisposing factors are female gender, poor bone stock, rotationally constrained implants, stress risers such as screw holes around the knee, malalignment of the prosthesis, endosteal ischaemia (bone cement, spongiosa preparation), anterior femoral notching, arthrofibrosis, chronic steroid use, rheumatoid arthritis, revision total knee arthroplasties, poliomyelitis and Parkinson’s disease (Table 1, Aaron & Scott, 1987; Ayers, 1997; Berry, 1999; Bogoch et al., 1987; Cain et al., 1986; Cordeiro et al., 1990; Culp et al., 1987; Diehl et al., 2006; DiGioa et al., 1991; Figgie et al., 1990; Haddad et al., 1999; Hirsh et al., 1981; Lesh et al., 2000; Merkel et al., 1986; Moran et al., 1996; Ritter et al., 1988; Roscoe et al., 1989; Shawen et al., 2003; Short et al., 1981; Sisto et al., 1985; Wick et al., 2004; Zehntner & Ganz, 1993). A biomechanical study has shown that notching of the anterior cortex significantly lessens the load to failure by decreasing the bending strength by 18% and the torsional strength by approximately 40% (Lesh et al., 2000). In a retrospective study, the clinical results of 1089 consecutive total knee replacements demonstrated no difference in knees managed with or without anterior femoral notching (Ritter et al., 2005). This finding emphasises the potential for osseous remodelling to decrease the risk of

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Locked plates combined with minimally invasive insertion technique for the treatment of periprosthetic supracondylar femur fractures above a total knee arthroplasty.

OBJECTIVE New locked plate devices offer theoretical advantages for the treatment of supracondylar femur fractures associated with a total knee arthroplasty (TKA). These devices also can be inserted with relative ease by using minimally invasive techniques, provide a fixed angle construct, and improve fixation in osteoporotic bone. The purpose of this study was to evaluate the results and compl...

متن کامل

Periprosthetic Fractures Following Total Knee Arthroplasty

Periprosthetic fractures after total knee arthroplasty may occur in any part of the femur, tibia and patella, and the most common pattern involves the supracondylar area of the distal femur. Supracondylar periprosthetic fractures frequently occur above a well-fixed prosthesis, and risk factors include anterior femoral cortical notching and use of the rotational constrained implant. Periprosthet...

متن کامل

Periprosthetic fractures around the knee—the best way of treatment

BACKGROUND A variety of methods has been described to stabilise periprosthetic fractures around total knee arthroplasty (TKA). Our report offers a review of the actual strategies in the reduction and fixation of these fractures. Surgical treatment should be based on the following four steps:Diagnostics: By taking the patients' history together with an X-ray of the knee and femur, the fracture i...

متن کامل

Minimally Invasive Plate Osteosynthesis for Periprosthetic Distal Femoral Fractures after Total Knee Arthroplasty

PURPOSE To evaluate the outcomes of the treatment of distal femoral fractures using minimally invasive plate osteosynthesis following total knee arthroplasty (TKA). MATERIALS AND METHODS From July 2008 to October 2011, 14 patients were treated with minimally invasive plate osteosynthesis for periprosthetic fractures following TKA. The mean duration of follow-up was 19.2 months and the mean ag...

متن کامل

Effectiveness of Minimally Invasive Plate Osteosynthesis (MIPO) on Comminuted Tibial or Femoral Fractures

Background: Comminuted fractures happen frequently due to traumas. Fixation without opening the fracture site,known as minimally invasive plate osteosynthesis (MIPO), has recently become prevalent. This study has beendesigned to assess the outcomes of this treatment for tibial and femoral comminuted fractures.Methods: A total of 60 patients with comminuted femoral or tibial fractures were opera...