Performance Evaluation of Transmission Line Protection Characteristics with DSTATCOM Implementation

نویسندگان

  • Yasar Khan
  • Khalid Mahmood
  • Sanaullah Ahmad
چکیده

To meet with the ever-enhancing load demands, new transmission lines should be bolted-on in the existing power system but the economic and environmental concerns are major constraints to this addition. Hence utilities have to rely on the existent power system infrastructure with some modifications. To enhance controllability and boost power transfer potential of the existing power system the use of Flexible Alternating Current Transmission System (FACTS) device is the most viable modification. FACTS devices include Static VAR Compensator (SVC), thyristor controlled series capacitor (TCSC), Thyristor Controlled Reactor (TCR), Thyristor Switched Capacitor (TSC) and Self Commutated VAR compensators i.e. Static Synchronous Compensator (DSTATCOM). Among the FACTS devices, DSTATCOM is the most feasible choice because of its capability to furnish both leading and lagging reactive power, faster response time in comparison with others, smaller harmonic content, inrush current generation is minimum and the dynamic performance with variations of voltage is quite good. DSTATCOM has the ability to have effective control over various issues concerning AC power transmission. However, the Parameters of the protection devices in the present power system are set without taking into account the reaction of these FACTS devices. So in order to ascertain stability and reliability of power system, reaction of FACTS devices with the existent protection schemes must be thoroughly investigated. This paper aims to explore the deviations in the performance characteristics of transmission line protection due to installation of DSTATCOM on a 220KV EHV transmission line using theoretical as well as MATLAB/SIMULINK simulation models. The dynamic performance of a DSTATCOM connected to an existing transmission line system is evaluated when large industrial induction motor is started and voltage sags are introduced. Keywords—Power system analysis; DSTATCOM; transmission line loss minimization; distribution dynamic compensation; transmission losses and efficiency

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Lightning Performance and its Prevention for Quadruple-circuit Transmission Line with 220kV/110kV Voltage in a Tower

According to the physical process of discharge development of insulator that is struck by lightning, the lightning flashover model for quadruple-circuit transmission line with dual voltage 220kV/110kV in same tower is established basing on EMTP. The actual evaluation index of lightning protection performance is adopted with the consideration of influence of system voltage. The characteristics o...

متن کامل

ارائه یک طرح حفاظت ویژه برای مقابله با پیشامدهای شدید ناحیه فارس در جنوب شبکه سراسری ایران

In the recent years use of Special Protection Schemes due to impact of notable these schemes in improving the performance of power systems  has found increasing usage. The purpose of this paper is design a suitable and fast special protection schemes to deal with extreme contingency that will led to collapse of power network if they occurred. So at the first, for a clear form of power tran...

متن کامل

Current Directional Protection of Series Compensated Line Using Intelligent Classifier

Current inversion condition leads to incorrect operation of current based directional relay in power system with series compensated device. Application of the intelligent system for fault direction classification has been suggested in this paper. A new current directional protection scheme based on intelligent classifier is proposed for the series compensated line. The proposed classifier uses ...

متن کامل

Performance Evaluation of Fault Location Algorithm for Protection of Series Compensated Transmission Line

In this paper, performance evaluation of different schemes for location of fault in series compensated transmission lines are presented. A fault location algorithm using two end measurements and another fault location algorithm using one end measurements for transmission lines with series compensator at midpoint are simulated and results are obtained. Both the schemes are compared on the basis ...

متن کامل

Eff ect of Series FACTS Devices on Distance Protection

The increase in the line complexity, confi guration and the power transmitted has introduced a number of problems in relation to protection. New techniques have become necessary to tackle these problems. Firstly it has become necessary to see that lines are not unnecessarily disconnected, but at the same time shorter operating times from protective relays are demanded on faulted sections to pre...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017