Heteroscedastic controlled calibration model applied to analytical chemistry
نویسنده
چکیده
In chemical analysis made by laboratories one has the problem of determining the concentration of a chemical element in a sample. In order to tackle this problem the guide EURACHEM/CITAC recommends the application of the linear calibration model, so implicitly assume that there is no measurement error in the independent variable X. In this work, it is proposed a new calibration model assuming that the independent variable is controlled. This assumption is appropriate in chemical analysis where the process tempting to attain the fixed known value X generates an error and the resulting value is x, which is not an observable. However, observations on its surrogate X are available. A simulation study is carried out in order to verify some properties of the estimators derived for the new model and it is also considered the usual calibration model to compare it with the new approach. Three applications are considered to verify the performance of the new approach.
منابع مشابه
Simultaneous spectrophotometric determination of ampicillin and penicillin in human plasma using multivariate calibration
An analytical methodology based on spectrophotometric and partial least squares (PLS) algorithm for thesimultaneous determination of ampicillin and penicillin in human plasma was developed and validated. Themultivariate model was developed as a binary calibration model and it was built and validated with anindependent set of synthesis and real samples in presence of matrix. It is shown how a de...
متن کاملFluorometric determination of mixtures of quinolones by means of partial least squares and neural networks.
Multivariate calibration methods (partial least squares calibration, back propagation multilayer perceptrons networks, radial basis functions and generalized regression neural networks) were applied to the simultaneous fluorometric quantification of levofloxacin, garenoxacin and grepafloxacin, without previous separation steps. A data matrix was obtained by registering the emission spectra of m...
متن کاملMitigation of Rayleigh and Raman spectral interferences in multiway calibration of excitation-emission matrix fluorescence spectra.
A weighted parallel factor analysis (W-PARAFAC) model is applied to excitation-emission matrix (EEM) fluorescence spectra of carbamate pesticides to aid with calibration in the presence of Raman scattering. Traditional PARAFAC inefficiently models the Raman scattering, resulting in prediction and calibration errors when a significant background is present. Four different weighting strategies we...
متن کاملModel updating for spectral calibration maintenance and transfer using 1-norm variants of Tikhonov regularization.
In this study, calibration maintenance confronts the problem of updating a model developed in the primary condition to accurately predict the calibrated analyte in samples measured in new secondary conditions. Calibration transfer refers to updating a model based on a primary instrument to predict samples measured on new secondary instruments. A 2-norm variant of Tikhonov regularization (TR) ha...
متن کاملElimination of the uninformative calibration sample subset in the modified UVE(Uninformative Variable Elimination)-PLS (Partial Least Squares) method.
In order to increase the predictive ability of the PLS (Partial Least Squares) model, we have developed a new algorithm, by which uninformative samples which cannot contribute to the model very much are eliminated from a calibration data set. In the proposed algorithm, uninformative wavelength (or independent) variables are eliminated at the first stage by using the modified UVE (Uninformative ...
متن کامل