Retrospective Review on Accuracy: A Pilot Study of Robotically Guided Thoracolumbar/Sacral Pedicle Screws Versus Fluoroscopy-Guided and Computerized Tomography Stealth-Guided Screws

نویسندگان

  • Brian Fiani
  • Syed A Quadri
  • Vivek Ramakrishnan
  • Blake Berman
  • Yasir Khan
  • Javed Siddiqi
چکیده

Introduction Pedicle screw insertion is the mainstay of thora-cic and lumbosacral posterior spinal instrumentation. However, it may be associated with complications such as screw mal-positioning. The purpose of this study was to develop a pilot study to compare the accuracy of robot-guided screw insertion versus hand-guided screw placement for spinal instrumentation. The hand-guided screws were placed with assistance from computerized tomography (CT) stealth guidance or fluoroscopy. Materials and methods A retrospective analysis of medical records was done for all patients that had pedicle screw insertion for instrumentation between the dates of December 2013 and January 2016 with post-screw placement CT imaging. The analysis was conducted on screw accuracy between the two categories based on the Gertzbein-Robbins classification. Results A total of 49 screws were analyzed for accuracy in six patients. There was no statistically significant difference between the accuracy of hand-placed pedicle screws versus the robotically placed screws (p = 0.311). There was no statistically significant difference in blood loss (p = 0.616), length of procedure (p = 0.192), or post-operative length of stay (p = 0.587). Conclusion The findings of our pilot study agree with most prior studies that there was no statistically significant difference in the accuracy of pedicle screw placement between the two methods of screw placement. Therefore, the techniques are equivocal in accuracy. The new technology (robotic-guidance) is as safe as conventional techniques for screw placement. Just like in any surgery, the technique preference should remain surgeon dependent. The results are only from a small sample size in the development of a pilot study so a strong reliance on the data would not be suggested. The study was a preliminary study that will be used as a template and learning process to create a future prospective study to investigate CT stealth and robotically guided screw placement versus "free hand" guided screws.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy and Safety in Pedicle Screw Placement in the Thoracic and Lumbar Spines : Comparison Study between Conventional C-Arm Fluoroscopy and Navigation Coupled with O-Arm® Guided Methods

OBJECTIVE The authors performed a retrospective study to assess the accuracy and clinical benefits of a navigation coupled with O-arm® system guided method in the thoracic and lumbar spines by comparing with a C-arm fluoroscopy-guided method. METHODS Under the navigation guidance, 106 pedicle screws inserted from T7 to S1 in 24 patients, and using the fluoroscopy guidance, 204 pedicle screws ...

متن کامل

Computed tomography-based navigation-assisted pedicle screw insertion for thoracic and lumbar spine fractures.

BACKGROUND Incorrect placement of pedicle screws may lead to neurovascular injury, so the position is important for the reduction of spinal fractures. CT-based image-guided surgery has been promoted as a means to theoretically improve the accuracy of pedicle screw placement. Patients who underwent CT-based navigation-assisted pedicle screw fixation for thoracic or lumbar fractures were reviewed...

متن کامل

Accuracy of image-guided pedicle screw placement using intraoperative computed tomography-based navigation with automated referencing. Part II: thoracolumbar spine.

BACKGROUND Image-guided spinal instrumentation may reduce complications in spinal instrumentation. OBJECTIVE To assess accuracy, time efficiency, and staff radiation exposure during thoracolumbar screw instrumentation guided by intraoperative computed tomography (iCT)-based neuronavigation (iCT-N). METHODS In 55 patients treated for idiopathic and degenerative deformities, 826 screws were i...

متن کامل

Lung Lesions Biopsy in Children by Computed Tomography (CT) Fluoroscopy Guided Versus Conventional CT Scan Guided

Abstract Background Computed tomography (CT)-guided biopsy of the lung is a well-established method of diagnosis. The aim of this study was to determine the success rate of fluoroscopic CT (FCT) and conventional CT (CCT) in needle navigation biopsies from the lung lesions. Materials and Methods A total of 78 patients were prospectively enrolled to receive CT-guided biopsy with (group I, n=2...

متن کامل

Image-guIded surgery In the spIne: neuronavIgatIon vs. fluoroscopy

Objectives: To evaluate the accuracy and the operative complications of implanting pedicle screws in the thoracic and lumbar spine, using computer-assisted surgery compared to the implantation technique using fluoroscopy. Methods: A retrospective study was conducted at the Hospital Universitário Cajuru PUC-PR from January 2000 to January 2009. Two groups of patients undergoing implant pedicle s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2017