Transverse forces in skeletal muscle with massage-like loading in a rabbit model

نویسندگان

  • Thomas M Best
  • Scott K Crawford
  • Caroline Haas
  • Lawrence Charles
  • Yi Zhao
چکیده

BACKGROUND The objective of this study was to quantify the transverse forces in skeletal muscle subjected to constant compressive massage-like loading (MLL) following eccentric exercise (ECC). METHODS Twenty-eight New Zealand White rabbits were used for this two-part study. For all testing, a customized electromechanical device was utilized to apply a constant compressive force MLL to the tibialis anterior (TA) muscle and the resultant transverse forces were quantified. The device consisted of two stepper motors that were positioned orthogonally to each other and connected to separate sliding tracks. A stainless steel cylindrical massage tip was mounted to a customized two-axis sensor consisting of two strain gauges with which forces along the two axes were measured. First, we determined the effects of tissue loading frequency and compression magnitude on transverse forces in the TA. Following a bout of ECC, sixteen rabbits were randomly assigned to a protocol with MLL frequency of 0.25 Hz or 0.5 Hz at a constant compressive force of 5 N or 10 N. Secondly, we utilized a protocol of 0.5 Hz, 10 N, 15 min MLL that was performed on 4 consecutive days commencing immediately post ECC (n = 6 animals) or 48 hours following ECC (n = 6 animals). Transverse forces were measured during all 4 MLL sessions for the entire 15 min duration for both the immediate and the delayed groups. RESULTS Both frequency and magnitude of compressive force due to MLL showed an effect on the magnitude of transverse force (p < 0.05 for each parameter). Furthermore, MLL beginning immediately following ECC produced higher transverse forces than MLL delayed by 48 hours with an average 20% difference between the two MLL groups over the four day protocol. Forces were higher in the middle 5 minutes compared to the first 5 minutes for all MLL bouts in both groups. CONCLUSIONS Frequency and magnitude of MLL and timing for delivery of MLL following ECC affect resultant transverse force values for exercised muscle. The application of our findings to humans receiving massage following exercise remains unknown at this time.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A new reduced mathematical model to simulate the action potential in end plate of skeletal muscle fibers

Usually mathematicians use Hodgkin-Huxley model or FitzHug-Nagumo model to simulate action potentials of skeletal muscle fibers. These models are electrically excitable, but skeletal muscle fibers are stimulated chemically. To investigate skeletal muscle fibers we use a model with six ordinary differential equations. This dynamical system is sensitive to initial value of some variables so it is...

متن کامل

In vivo passive mechanical properties of skeletal muscle improve with massage-like loading following eccentric exercise.

A quasi-linear viscoelasticity (QLV) model was used to study passive time-dependent responses of skeletal muscle to repeated massage-like compressive loading (MLL) following damaging eccentric exercise. Six skeletally mature rabbits were surgically instrumented with bilateral peroneal nerve cuffs for stimulation of the hindlimb tibialis anterior (TA) muscles. Following the eccentric exercise, r...

متن کامل

Immunomodulatory effects of massage on nonperturbed skeletal muscle in rats.

Massage is an ancient manual therapy widely utilized by individuals seeking relief from various musculoskeletal maladies. Despite its popularity, the majority of evidence associated with massage benefits is anecdotal. Recent investigations have uncovered physiological evidence supporting its beneficial use following muscle injury; however, the effects of massage on healthy, unperturbed skeletal...

متن کامل

Dose-dependency of massage-like compressive loading on recovery of active muscle properties following eccentric exercise: rabbit study with clinical relevance.

BACKGROUND Optimal strategies for massage and its use in athletes have not been conclusively demonstrated. PURPOSE/STUDY DESIGN: Effects of varying duration, frequency and magnitude of massage-like compressive loading (MLL) on recovery of skeletal muscle active properties (torque angle (T-Θ) relationship) following exercise-induced muscle injury were studied. METHODS Twenty-four New Zealan...

متن کامل

Effects of ionic parameters on behavior of a skeletal muscle fiber model

All living cells have a membrane which separates inside the cell from it's outside. There is a potential difference between inside and outside of the cell. This potential difference will change during an action potential. It is quite common to peruse action potentials of skeletal muscle fibers with the Hodgkin-Huxley model. Since Hodgkin and Huxley summarized some controlling currents like inwa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2014