An experimental study of winding vibration of a single-phase power transformer using a laser Doppler vibrometer ¬リニ

نویسندگان

  • Jing Zheng
  • Jie Pan
  • Hai Huang
چکیده

Transformer tank vibration has been used for the condition monitoring and fault diagnosis of power transformers, as well as for the evaluation of radiated sound power from such power transformers. In both applications, seeking a correlation between transformer tank vibration and the vibration of the transformer windings and core becomes a challenge for fault identification and noise control at the sources of vibration and noise. The purpose of this paper is to experimentally investigate the winding vibration of an electrically live power transformer and characterize the changes in the spatial and frequency features of the vibration as various mechanical faults are introduced to the transformer winding. To avoid the effects of transducer loading and electromagnetic fields on the measurement results, a laser Doppler vibrometer was used to make non-contact measurements of the winding vibration. 2014 Elsevier Ltd. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Power Auto-transformer Mechanical Faults Diagnosis ‎Using Finite Element based FRA

Frequency response analysis (FRA) is a sensitive ‎method established for testing the mechanical integrity of ‎transformers. However, interpretation of FRA signature still ‎needs expert opinions and there is no FRA interpretation code ‎generally accepted. Various mechanical faults with different ‎extents on power transformers are required to aid FRA ‎interpretation. To address this challenge, in...

متن کامل

Characterization of Power Transformer Electromagnetic Forces Affected by Winding Faults

Electromagnetic forces in power transformer windings are produced by interaction between the leakage fluxes and current passing them. Since the leakage flux distribution along the windings height is in two axial and radial directions, so the electromagnetic forces have two components, radial and axial. There is a risk that a large electromagnetic force due to the short circuit or inrush current...

متن کامل

Recognition and Location of Power Transformer Turn to Turn Fault by Analysis of Winding Imposed Forces

Turn to turn fault is one of the major internal failures in the power transformers that if it is not quickly detected, can be extended and led to a complete transformer breakdown. So, the diagnosis and location of the turn to turn fault of the power transformer, as one of the most important equipment in the power system, is the main objective of this paper. For this purpose, a detailed model of...

متن کامل

Efficiency Improvement of the Flyback Converter Based on High Frequency Transformer Winding Rearrangement

In this paper, a novel method for loss reduction and efficiency optimization of the high frequency flyback transformers is proposed based on rearrangement of the windings. According to detailed analysis of the high frequency flyback transformer using FEM technique, a novel and simple approach for its design improvement and loss reduction is introduced. It is shown that leakage flux scattering i...

متن کامل