Evaluation of head-of-bed elevation compliance in critically ill patients under mechanical ventilation in a polyvalent intensive care unit.
نویسندگان
چکیده
OBJECTIVES To evaluate head-of-bed elevation (HOBE) compliance in mechanically ventilated (MV) patients during different time periods, in order to identify factors that may influence compliance and to compare direct-observation compliance with checklist-reported compliance. DESIGN AND SETTING A prospective observational study was carried out in a polyvalent Intensive Care Unit. PATIENTS All consecutive patients with MV and no contraindication for semi-recumbency were studied. INTERVENTION AND VARIABLES HOBE was observed during four periods of one month each for one year, the first period being blinded. HOBE was measured with an electronic device three times daily. Main variables were HOBE, type of airway device, type of bed, nursing shift, day of the week and checklist-reported compliance. No patient characteristics were collected. RESULTS During the four periods, 2639 observations were collected. Global HOBE compliance was 24.0%, and the median angle head-of-bed elevation (M-HOBE) was 24.0° (IQR 18.8-30.0). HOBE compliance and M-HOBE by periods were as follows: blinded period: 13.8% and 21.1° (IQR 16.3-24.4); period 1: 25.5% and 24.3° (IQR 18.8-30.2); period 2: 22.7% and 24.4° (IQR 18.9-29.6); and period 3: 31.4% and 26.7° (IQR 21.3-32.6) (p<0.001). An overestimation of 50-60% was found when comparing self-reported compliance using a checklist versus direct-observation compliance (p<0.001). Multivariate logistic regression analysis found the presence of an endotracheal tube (ET) and bed without HOBE measuring device to be independently associated to greater compliance (p<0.05). CONCLUSIONS Although compliance increased significantly during the study period, it was still not optimal. Checklist-reported compliance significantly overestimated HOBE compliance. The presence of an ET and a bed without HOBE measuring device was associated to greater compliance.
منابع مشابه
Association between admission hypomagnesemia mortality or mortality of critically ill patients in intensive care unit
Background: Up to now there is no study evaluating correlation between serum magnesium and morbidity or mortality in patients admitted in intensive care unit. The aim of this study is to determine the prevalence of hypomagnesemia in critically ill patients and to evaluate its association with organ dysfunction, hospitalization period and mortality. Methods: We conducted a retrospective trial ...
متن کاملExposure keratitis in mechanical ventilatory patients admitted to intensive care unit
Background & Aims: Exposure Keratitis (EK) is a common problem in critically ill patients admitted to the Intensive Care Unit (ICU). We conducted exposure keratitis in mechanical ventilatory patients in the intensive care unit of Imam Khomeini Hospital in Urmia for five years. Materials & Methods: In this retrospective cross-sectional study, the records of the patients were taken from the medi...
متن کاملThe relationship of serum vitamin D level with the outcome in surgical intensive care unit patients
The aim of this study was to assess the correlation of serum vitamin D with ICU length of stay, mortality rate, length of mechanical ventilation, and incidence of sepsis. We conducted a descriptive analytic study on 793 patients admitted to surgical ICU wards in northwest of Iran from March 2015 to March 2016. Patients were assessed during the ICU stay and the following data were collect...
متن کاملHead-of-bed elevation in critically ill patients: a review.
Clinicians are confused by conflicting guidelines about the use of head-of-bed elevation to prevent aspiration and pressure ulcers in critically ill patients. Research-based information in support of guidelines for head-of-bed elevation to prevent either condition is limited. However, positioning of the head of the bed has been studied more extensively for the prevention of aspiration than for ...
متن کاملThe relationship of serum vitamin D level with the outcome in surgical intensive care unit patients
The aim of this study was to assess the correlation of serum vitamin D with ICU length of stay, mortality rate, length of mechanical ventilation, and incidence of sepsis. We conducted a descriptive analytic study on 793 patients admitted to surgical ICU wards in northwest of Iran from March 2015 to March 2016. Patients were assessed during the ICU stay and the following data were collect...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Medicina intensiva
دوره 39 6 شماره
صفحات -
تاریخ انتشار 2015