Feasibility of real-time three-dimensional transoesophageal echocardiography for guidance of percutaneous atrial septal defect closure.

نویسندگان

  • Joseph A Lodato
  • Qi Ling Cao
  • Lynn Weinert
  • Lissa Sugeng
  • John Lopez
  • Roberto M Lang
  • Ziyad M Hijazi
چکیده

AIMS Intracardiac echocardiography (ICE) and two-dimensional transoesophageal echocardiography (2D TEE) are used in most centres for guiding transcatheter atrial septal defect (ASD) closure. ASDs have complex shapes that are not well characterized with 2D imaging. Real-time 3D TEE (RT3D TEE) provides en-face visualization of the ASD, allowing precise assessment of ASD dimensions. Accordingly, our aims were (i) to determine the feasibility of RT3D TEE to guide ASD closure and (ii) to compare ASD and balloon dimensions (BDs) using RT3D TEE vs. ICE and 2D TEE. METHODS AND RESULTS Thirteen patients with ostium secundum ASD underwent transcatheter ASD closure. 2D TEE, RT3D TEE, and ICE images were acquired sequentially. RT3D TEE was feasible in all patients. Comparing RT3D TEE and 2D imaging, the mean difference in long-axis dimension was +0.5 mm (P= NS for both), and -1.4 mm in short-axis (2D TEE, P < 0.05; ICE, P = 0.06). BD was greater with 3D TEE vs. ICE (+0.9 mm). CONCLUSION RT3D TEE can be used to guide transcatheter ASD closure with the advantages of lower cost than ICE, and ability to visualize en-face views of the ASD. ASD and BD as measured by RT3D TEE differ when compared with 2D imaging.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transcatheter closure of multiple atrial septal defects. Initial results and value of two- and three-dimensional transoesophageal echocardiography.

AIMS To examine the feasibility of transcatheter closure of multiple atrial septal defects using two Amplatzer devices simultaneously and to describe the importance and the role of two- and three-dimensional transoesophageal echocardiography in the selection and closure of such defects. METHODS Twenty-two patients with more than one atrial septal defect underwent an attempt at transcatheter c...

متن کامل

Three-dimensional echo-guided beating heart surgery without cardiopulmonary bypass: atrial septal defect closure in a swine model.

OBJECTIVE In this study, we tested 3 techniques of atrial septal defect closure under real-time 3-dimensional echocardiography guidance in a swine model. METHODS The operations were conducted under the sole guidance of a modified real-time 3-dimensional echocardiography guidance system with a x4 matrix transducer (Sonos 7500, Philips Medical Systems, Andover, Mass). Eighteen swine were anesth...

متن کامل

Cryptogenic stroke after percutaneous closure of an atrial septal defect.

We present the case of a patient who underwent a percutaneous secundum atrial septal defect (ASD II) closure with an undersized septal occluder device. One week and one month later she experienced two transient ischemic attacks. Three-dimensional transesophageal echocardiography (TEE) revealed a residual patent foramen ovale (PFO) with a positive Valsalva bubble test. She underwent a second pro...

متن کامل

Percutaneous transjugular device closure of postoperative residual atrial septal defect.

Percutaneous closure of postoperative malaligned residual atrial septal defect was successfully performed from the transjugular approach under transesophageal echocardiography guidance in a 38-year-old symptomatic woman with patent femoral venous access using the usual hardware. This demonstrates the feasibility of transjugular approach as an alternative to femoral or transhepatic approaches in...

متن کامل

Percutaneous closure of a post-myocardial infarction ventricular septal defect guided by real-time three-dimensional echocardiography.

We present an adult patient who had an acute myocardial infarction complicated by a ventricular septal defect and had it repaired percutaneously. Real-time three-dimensional echocardiography (RT3D) before and during the closure procedure were performed. RT3D provided anatomical and functional information of the defect as well as real-time guidance during the procedure. This case highlights the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology

دوره 10 4  شماره 

صفحات  -

تاریخ انتشار 2009