Spin echo versus stimulated echo diffusion tensor imaging of the in vivo human heart
نویسندگان
چکیده
PURPOSE To compare signal-to-noise ratio (SNR) efficiency and diffusion tensor metrics of cardiac diffusion tensor mapping using acceleration-compensated spin-echo (SE) and stimulated echo acquisition mode (STEAM) imaging. METHODS Diffusion weighted SE and STEAM sequences were implemented on a clinical 1.5 Tesla MR system. The SNR efficiency of SE and STEAM was measured (b = 50-450 s/mm(2) ) in isotropic agar, anisotropic diffusion phantoms and the in vivo human heart. Diffusion tensor analysis was performed on mean diffusivity, fractional anisotropy, helix and transverse angles. RESULTS In the isotropic phantom, the ratio of SNR efficiency for SE versus STEAM, SNRt (SE/STEAM), was 2.84 ± 0.08 for all tested b-values. In the anisotropic diffusion phantom the ratio decreased from 2.75 ± 0.05 to 2.20 ± 0.13 with increasing b-value, similar to the in vivo decrease from 2.91 ± 0.43 to 2.30 ± 0.30. Diffusion tensor analysis revealed reduced deviation of helix angles from a linear transmural model and reduced transverse angle standard deviation for SE compared with STEAM. Mean diffusivity and fractional anisotropy were measured to be statistically different (P < 0.001) between SE and STEAM. CONCLUSION Cardiac DTI using motion-compensated SE yields a 2.3-2.9× increase in SNR efficiency relative to STEAM and improved accuracy of tensor metrics. The SE method hence presents an attractive alternative to STEAM based approaches. Magn Reson Med 76:862-872, 2016. © 2015 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
منابع مشابه
Direct comparison of in-vivo and post-mortem spin-echo based diffusion tensor imaging in the porcine heart
Background Spin-echo based cardiac diffusion tensor imaging (DTI) is highly sensitive to myocardial strain [1]. Imaging during systolic contraction requires precise planning of the sequence timing [2]. Second order motion compensated diffusion encoding has recently been proposed for small animal imaging [3] to reduce the impact of myocardial strain on the diffusion tensor. It is the objective o...
متن کاملSecond order motion compensated spin-echo diffusion tensor imaging of the human heart
PURPOSE Myocardial microstructure has been challenging to probe in vivo. Spin echo-based diffusion-weighted sequences allow for single-shot acquisitions but are highly sensitive to cardiac motion. In this study, the use of second-order motion-compensated diffusion encoding was compared with first-order motion-compensated diffusion-weighted imaging during systolic contraction of the heart. MET...
متن کاملSecond order motion compensated spin echo cardiac diffusion tensor imaging on clinical MR systems
Background Recently second order motion compensated spin echo (SE) sequences in conjunction with high performance gradient systems have been proposed for diffusion weighted (DWI) [1] and diffusion tensor imaging (DTI) [2,3] of the human in vivo heart. The method allows for free breathing acquisition without requiring dedicated patient feedback systems or other provisions [4], facilitating the t...
متن کاملFeasibility of in vivo whole heart DTI and IVIM with a 15 minute acquisition protocol
Background In recent years in vivo cardiac DTI using stimulated echo’s (STE) has matured into a reproducible technique. However the STE approach requires two heartbeats and intrinsically has a 50% lower SNR compared to spin-echo (SE). Although the STE method allows for short TE (23 ms) it also suffers from T1 signal decay and typically 8 signal averages (16 heartbeats) are needed for a single s...
متن کاملDiffusion-tensor MR imaging of the human brain with gradient- and spin-echo readout: technical note.
Diffusion-tensor MR imaging of the brain is an objective method that can measure diffusion of water in tissue noninvasively. Five adult volunteers participated in this study that was performed to evaluate the potential of gradient- and spin-echo readout for diffusion-tensor imaging by comparing it with single-shot spin-echo echo-planar imaging. Gradient- and spin-echo readout provides comparabl...
متن کامل