Outcome With the Repositionable and Retrievable Boston Scientific Lotus Valve Compared With the Balloon-Expandable Edwards Sapien 3 Valve in Patients Undergoing Transfemoral Aortic Valve Replacement.

نویسندگان

  • Julia Seeger
  • Birgid Gonska
  • Wolfgang Rottbauer
  • Jochen Wöhrle
چکیده

BACKGROUND New generation devices for transfemoral aortic valve replacement were optimized on valve positioning and reduction of residual aortic regurgitation. We compared 30-day, 12-month, and 24-month outcomes of the Boston Scientific Lotus valve (Lotus) and the balloon-expandable Edwards Sapien 3 (ES3) valve. Primary end point was all-cause mortality or disabling stroke within 12 months. METHODS AND RESULTS Between 2014 and 2016, 537 patients were enrolled at our center, and 202 patients received Lotus and 335 ES3. There was no residual moderate or severe aortic regurgitation. Rate of mild aortic regurgitation was lower with the repositionable and retrievable Lotus valve compared with the ES3. Rate of pacemaker implantation was significantly higher with the Lotus valve compared with the ES3 valve (36.1% versus 14.9%, P<0.01). Valve Academic Research Consortium-2 early safety end point at 30 days was 7.4% with both devices with no difference in all-cause mortality (Lotus, 1.9%; ES3, 1.8%; P=0.87), rate of disabling stroke (Lotus, 1.5%; ES3, 2.1%; P=0.62), or major vascular complications (Lotus, 2.9%; ES3, 2.4%; P=0.69). The primary end point at 12 months was similar between groups. In a propensity score-matched comparison, there was no difference in the primary end point within 12 months (Lotus, 15.5%; ES3, 18.6%; P=0.69) and 24 months (Lotus, 21.9%; ES3, 26.4%; P=0.49). CONCLUSIONS Transfemoral aortic valve replacement with the ES3 and the Lotus were associated with similar 30-day, 12-month, and 24-month clinical outcomes. Need for permanent pacemaker implantation was significantly higher with the repositionable Lotus device. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT02162069.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Repositionable Versus Balloon‐Expandable Devices for Transcatheter Aortic Valve Implantation in Patients With Aortic Stenosis

BACKGROUND The safety and effectiveness of the fully repositionable LOTUS valve system as compared with the balloon-expandable Edwards SAPIEN 3 prosthesis for the treatment of aortic stenosis has not been evaluated to date. METHODS AND RESULTS All patients undergoing transcatheter aortic valve implantation with the Edwards SAPIEN 3 or the LOTUS valve system were included into the Swiss Transc...

متن کامل

The safety of introducing a new generation TAVR device: one departments experience from introducing a second generation repositionable TAVR

BACKGROUND In the evolving field of transcatheter aortic valve replacements a new generation of valves have been introduced to clinical practice. With the complexity of the TAVR procedure and the unique aspects of each TAVR device, there is a perceived risk that changing or adding a new valve in a department could lead to a worse outcome for patients, especially during the learning phase. The o...

متن کامل

Prospective analysis of 30-day safety and performance of transfemoral transcatheter aortic valve implantation with Edwards SAPIEN XT versus SAPIEN prostheses.

BACKGROUND A new generation of balloon-expandable valves (e.g. Edwards SAPIEN XT) enables the use of a decreased sheath size using the NovaFlex™ delivery system for transfemoral transcatheter aortic valve implantation (TAVI). However, there are few data analysing the efficacy and safety of this new prosthesis. AIMS To evaluate periprocedural and 30-day clinical outcomes using the Edwards SAPI...

متن کامل

1-Year Outcomes After Transcatheter Aortic Valve Replacement With Balloon-Expandable Versus Self-Expandable Valves: Results From the CHOICE Randomized Clinical Trial.

BACKGROUND The use of a balloon-expandable transcatheter heart valve previously resulted in a greater rate of device success compared with a self-expandable transcatheter heart valve. OBJECTIVES The aim of this study was to evaluate clinical and echocardiographic outcome data at longer term follow-up. METHODS The investigator-initiated trial randomized 241 high-risk patients with symptomati...

متن کامل

1-Year Outcomes With the Fully Repositionable and Retrievable Lotus Transcatheter Aortic Replacement Valve in€120 High-Risk Surgical Patients With Severe Aortic Stenosis

OBJECTIVES This analysis presents the first report of 1-year outcomes of the 120 patients enrolled in the REPRISE II (Repositionable Percutaneous Placement of Stenotic Aortic Valve Through Implantation of Lotus Valve System– Evaluation of Safety and Performance) study. BACKGROUND The fully repositionable and retrievable Lotus Valve (Boston Scientific, Marlborough, Massachusetts) was designed to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Cardiovascular interventions

دوره 10 6  شماره 

صفحات  -

تاریخ انتشار 2017