Ultrasensitive gaseous NH3 sensor based on ionic liquid-mediated signal-on electrochemiluminescence.
نویسندگان
چکیده
This work reports that ammonia (NH(3)) can be used as an efficient co-reactant for tris(2,2'-bipyridine)ruthenium(II) (Ru(bpy)(3)(2+)) electrochemiluminescence (ECL) in ionic liquids (ILs), on the basis of which a signal-on ECL sensor for directly detecting gaseous NH(3) has been developed. The NH(3) ECL sensor has a very high sensitivity, with a detection limit of 10 ppt NH(3) (at signal-to-noise ratio of 3) without any preconcentration. The high sensitivity is mainly due to the zero ECL background of Ru(bpy)(3)(2+) in the ILs, strong co-reactant ECL activity of NH(3), and high solubility of NH(3) in imidazolium-based ILs. Additionally, the ECL sensor shows an excellent selectivity against common interfering gases and a wide linear response range from 10 ppt to 10 ppm.
منابع مشابه
Synergistic Signal Amplification Based on Ionic Liquid-BaTiO3 Nanoparticle Carbon Paste Electrode for Sensitive Voltammetric Determination of Acetaminophen
Monitoring the acetaminophen in biological samples and also in pharmaceutical formulations is important due to the concerns of public health care and drug safety. In this work a carbon paste electrode modified with BaTiO3 nanoparticle (BTO NPs) and room-temperature ionic liquid (IL) (n-hexyl-3-methylimidazolium hexafluoro phosphate) was fabricated. The direct electro-oxidation behavior of aceta...
متن کاملAn electrochemiluminescent sensor based on functionalized conjugated polymer dots for the ultrasensitive detection of Cu2.
An ultrasensitive electrochemiluminescence (ECL) detection for Cu2+ was explored using the carboxyl functionalized poly(9,9-dioctylfluorenyl-2,7-diyl) (PS-COOH-co-PFO) dots as the signal label without adding any coreactant.
متن کاملIn-situ preconcentration, and electrochemical sensing of Zinc(II) and Copper(II) based on ionic liquid mediated hollow fiber-modified pencil graphite electrode using response surface methodology
A single-use electrochemical sensor using ionic liquid mediated hollow fiber-graphite working electrode was fabricated for the first time. The screening tool was developed by coupling this electrode with differential pulse voltammetry (DPV) for in-situ pre-concentration and determination of Zn(II) and Cu(II). In our plot, porous polypropylene hollow fiber membrane divided into pieces of 2 cm, t...
متن کاملIn-situ preconcentration, and electrochemical sensing of zinc(II) and copper(II) based on ionic liquid mediated hollow fiber-modified pencil graphite electrode using response surface methodology
A single-use electrochemical sensor using ionic liquid mediated hollow fiber-graphite working electrode was fabricated for the first time. The screening tool was developed by coupling this electrode with differential pulse voltammetry (DPV) for in-situ pre-concentration and determination of Zn(II) and Cu(II). In our plot, porous polypropylene hollow fiber membrane was divided into pieces of 2 c...
متن کاملUultra-trace determination of cadmium (II) in aqueous environmental samples by a new ion selective electrode based on nefazodone and 1-butyl-3-methylimidazolium hexafluorophosphate ionic liquid
Background and Objective: Cadmium is a potential environmental contaminant that causes adverse effects on the environment and the health of living organisms. Therefore, designing a simple and economic technique for its determination is very important. In this respect, a potentiometric sensor based on nefazodone as the ionophore and [BMIM]PF6 as the ionic additive were developed for the determin...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Analyst
دوره 137 15 شماره
صفحات -
تاریخ انتشار 2012