Morphological resonances detected from a cluster of two microspheres.

نویسندگان

  • S Arnold
  • A Ghaemi
  • P Hendrie
  • K A Fuller
چکیده

Morphological resonances are detected in elastic scattering and fluorescence excitation spectra from a cluster of two spheres, each -5 /im in radius, isolated and oriented in an electrodynamic levitator trap. Light scattering at 90' and perpendicular to the line of centers of the particles, by broadside illumination with polarization in the scattering plane, shows that an independent particle model may be used in describing resonance positions and the shape of the spectrum, even though the joined particles differ in size by slightly less than 10 nm. In end-fire illumination the fluorescence excitation spectrum is missing a number of resonances that are seen with broadside illumination.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Taxonomic Reassessment of Consolida (Ranunculaceae) Species: Insight from Morphological and Molecular Data

In order to compare the efficiency of morphological traits and molecular markers in distinguishing the Consolida species, molecular analysis using nrDNA ITS and cpDNA trnL-trnF with maximum parsimony and Bayesian methods were done in a total of 34 species and forma representing 28 species of Consolida, 6 species of Aconitella, plus two species of Delphinium and two species of Aconitum as out gr...

متن کامل

Enhanced coupling to microsphere resonances with optical fibers

Morphology-dependent resonances (MDR’s) of polystyrene microspheres were excited by an optical fiber coupler. For optical elimination of the air–cladding interface at the optical fiber coupler surface, the microsphere was immersed in an index-matching oil. MDR’s were observed, even though the relative refractive index between the microsphere and the oil was only 1.09. The observed MDR spectra a...

متن کامل

Formulation and Evaluation of Propranolol Hydrochloride-Loaded Carbopol-934P/Ethyl Cellulose Mucoadhesive Microspheres

The purpose of this research was to formulate and systemically evaluate in-vitro and in-vivo performances of mucoadhesive propranolol hydrochloride microspheres for its potential use in the treatment of hypertension, myocardial infraction and cardiac arrhythmias. Propranolol hydrochloride mucoadhesive microspheres, containing carbopol-934P as mucoadhesive polymer and ethyl cellulose as carrier ...

متن کامل

Formulation and Evaluation of Propranolol Hydrochloride-Loaded Carbopol-934P/Ethyl Cellulose Mucoadhesive Microspheres

The purpose of this research was to formulate and systemically evaluate in-vitro and in-vivo performances of mucoadhesive propranolol hydrochloride microspheres for its potential use in the treatment of hypertension, myocardial infraction and cardiac arrhythmias. Propranolol hydrochloride mucoadhesive microspheres, containing carbopol-934P as mucoadhesive polymer and ethyl cellulose as carrier ...

متن کامل

Observation of nondegenerate cavity modes for a distorted cavity modes for a distorted polystyrene microsphere

Nondegenerate azimuthal morphology-dependent resonances are observed for a distorted, fluorescently labeled polystyrene microsphere levitated in a quadrupole ion trap. Modeling the individual resonances by using perturbation theory allows a determination of quadrupole and octupole distortion parameters. The particle’s shape changes slowly over the course of the measurement and eventually become...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optics letters

دوره 19 3  شماره 

صفحات  -

تاریخ انتشار 1994