Surface renewal method for estimating sensible heat flux
نویسندگان
چکیده
For short canopies, latent energy flux may be estimated using a shortened surface energy balance from measurements of sensible and soil heat flux and the net irradiance at the surface. The surface renewal (SR) method for estimating sensible heat, latent energy, and other scalar fluxes has the advantage over other micrometeorological methods since the method requires only measurement of the scalar of interest at a point and the method may be applied close to the canopy surface, thereby reducing fetch requirements. The SR analysis for estimating sensible heat flux from canopies involves highfrequency air-temperature measurements (typically 2 to 10 Hz) using unshielded and naturally-ventilated 25to 75-mm diameter fine-wire thermocouples. The SR method is based on the premise that a parcel of air connected to the surface, after it has been enriched or depleted, is renewed by an air parcel from above. There are 2 SR analysis approaches: the ideal SR analysis approach which presumes a constant α factor; and a set of SR approaches that avoid the use of the α calibration factor. The weighting factor α depends on measurement height, canopy structure and stability conditions since it depends on the capability of the highest frequency eddies to mix the scalar within the air parcels renewed by coherent structures. A combination approach using SR and either similarity theory, that requires friction velocity or wind-speed measurements, or dissipation theory, has also been used to estimate H. The combination SR and dissipation method only requires high-frequency air-temperature data and may be considered not to require calibration. The ideal SR and combination SR/ dissipation approaches are the least expensive micrometeorological methods for estimating sensible heat flux and also latent energy flux if one forces closure of the surface energy balance. However, application of SR analysis using slow data-loggers require some expertise since high-frequency air temperature data are not usually stored with the slower data-loggers. Some structure functions can be stored for post-processing and determination of ramp amplitude and ramp period, but the appropriate time lags have to be chosen a priori. Fortunately, modern data-loggers avoid this problem and complex SR analysis approaches can now be applied. However, for routine purposes, applications using the ideal SR analysis approach with slow data-loggers may be of interest since it is a very affordable method.
منابع مشابه
Estimating sensible and latent heat flux densities from grapevine canopies using surface renewal
Fine-wire thermocouples were used to measure high-frequency temperature above and within canopies and structure functions were employed to determine temperature ramp characteristics, which were used in a fundamental conservation of energy equation to estimate sensible heat flux density. Earlier experiments over dense, tall, and short canopies demonstrated that the surface renewal method works, ...
متن کاملEstimation of momentum and heat fluxes using dissipation and flux-variance methods in the unstable surface layer
Dissipation and flux-variance methods, derived from the turbulent kinetic energy and temperature variance budget equations in conjunction with Monin-Obukov similarity theory, were used to estimate surface fluxes of momentum and sensible heat. To examine the performance of these two methods, direct eddy correlation measurements were carried out above a nonuniform grass-covered forest clearing in...
متن کاملUsing Temperature Fluctuation Measurements to Estimate Meteorological Inputs for Modelling Dispersion During Convective Conditions in Urban Areas
We examine the performance of several methods to estimate meteorological 1 inputs for modelling dispersion in urban areas during convective conditions. Sensible heat 2 flux, surface friction velocity and turbulent velocities are estimated from measurements of 3 mean wind speed and the standard deviation of temperature fluctuations at a single level on a 4 tower at two suburban sites and at one ...
متن کاملComparison of Three Operative Models for Estimating the Surface Water Deficit using ASTER Reflective and Thermal Data
Three operative models with minimum input data requirements for estimating the partition of available surface energy into sensible and latent heat flux using ASTER data have been evaluated in a semiarid area in SE Spain. The non-evaporative fraction (NEF) is proposed as an indicator of the surface water deficit. The best results were achieved with NEF estimated using the “Simplified relationshi...
متن کاملA New Method for Estimation of the Sensible Heat Flux under Unstable Conditions Using Satellite Vector Winds
It has been difficult to estimate the sensible heat flux at the air–sea interface using satellite data because of the difficulty in remotely observing the sea level air temperature. In this study, a new method is developed for estimating the sensible heat flux using satellite observations under unstable conditions. The basic idea of the method is that the air–sea temperature difference is relat...
متن کامل