Quantitative determination of oil films/slicks from water surfaces using a modified solid- phase extraction (SPE) sampling method

نویسنده

  • P. Louchouarn
چکیده

We have developed a procedure using solid-phase extraction (SPE) for the quantitative determination of oil films and slicks floating on water surfaces. During Phase One of this study, nine oil loadings (Exxon #6 fuel oil: 3 to 38 mg/cm) were sub sampled with C18-SPE disks in replicates (n = 2-4) from the surface of 1L beakers. Sonication and accelerated solvent extraction (ASE) were both tested as extraction procedures and quantification was determined gravimetrically (Total Extractable Material or TEM) and following a laboratory procedure employing extraction of samples with dichloromethane and analysis using gas chromatographymass spectrometry (Total Petroleum Hydrocarbon or TPH). Based on these two quantification methods, the recovery efficiency of oil from the SPE pads was 95±6% and 98±14%, respectively, and no significant difference was observed between sonication and ASE extraction procedures. Moreover, a strong linearity was observed throughout the whole range of loadings with a precision of ~7% and a 1:1 sampling efficiency of TEM and TPH per unit area. In Phase Two, the method was tested on a controlled surface oil slick (9.5±1.1 m) in a salt-water mesocosm and using multiple SPE disks (n = 12). Although the TEM-based approach slightly overestimated the overall amount of spilled oil (127±41%) it suggests that the present sampling method can be used as a first approximation to the quantification of oil on water surfaces. Total Petroleum Hydrocarbon results, on the other hand, showed a much stronger potential for resolving the source of overestimation obtained using TEM (i.e. emulsification of oil/water and/or incorporation of non-oil products in the oil slick) as well as reducing the variability. Using this method the estimates of spilled oil ranged 105±25% suggesting that the SPE/TPH combined procedure can be used to quantify meso-scale to large-scale spills in experimental or natural settings with the added advantage of recovering material for oil fingerprinting. 1.0 Introduction Oil spills are as pervasive as our need for energy. Maybe more so when we realize that natural oil seeps in certain regions of the world Oceans, such as in the Gulf of Mexico, contribute substantial amounts of oil to marine environments that are comparable to large-scale accidental spills due to transport or drilling activities (MacDonald, 1998). However, although the quantities may be roughly equivalent, the rates are not. The case of the Exxon Valdez in Alaska or the Erika recently in South Brittany (France), are vivid examples of how anthropogenic influences impact coastal environments at a hurried pace. Rapid detection, and eventually quantification, of natural or anthropogenically-derived hydrocarbon slicks floating on water is crucial to reduce the consequences on safety and the environment. Although certain systems exist for detection of Proceedings of the 23 Arctic Marine Oil Spill Program Meeting, Vancouver, Canada. Vol. 1., 59-68 ______________________________________________________________________________ such slicks/films (MacDonald et al., 1993; MacDonald, 1998; Brown and Fingas, 1998, 1999; Seureau, 1999), there still exists a need for a method to evaluate slicks in a quantitative manner and simultaneously provide material for fingerprinting. More specifically, a method such as this one would provide a strong tool to assess the effectiveness of methods for clean-up of coastal substrates affected by oil spills. Chemical surface washing agents (shoreline cleaners) are formulated and used to help release stranded oil from shoreline substrates (rocky shores, sandy beaches, wetlands, mud-flats, etc.). The main role of the cleaner is to coalesce with the oil, strip it from the substrate and rise to the water surface where the mixture can be collected by mechanical procedures (booming or skimming). The objectives of this project were thus to test a modified solid-phase extraction (SPE) procedure using C-18 disks to determine 1) if surface sampling of oil slicks using this procedure is linear, precise, and consistently yields quantitative recoveries of oil per unit area, and 2) if this method can be used to quantify mesoto large-scale oil slick on water surfaces. Solid-phase extraction is now well recognized as a method for isolating hydrophobic organic compounds from aqueous solutions in preparation for subsequent analysis, and is used in a variety of applications (Donat et al., 1986; Jandera et al., 1994; Snyder et al., 1999; Louchouarn et al., 2000). We have applied this method in a new fashion to quantitatively recover oil for water surfaces. A related objective of this project was also to assess the effectiveness of oil removal from a sandy beach in meso-scale wave tanks using different shoreline cleaner products. The results of this selected work is presented in a companion paper appearing in these proceedings (Page et al., 2000). 2.0 Methods and Materials 2.1 The Oil Mixture The oil used in this experiment was Exxon #6 fuel oil since it is a common fuel oil in South Texas Bays and the Houston Ship Channel and it was selected in the related meso-scale shoreline cleaner study. Due to the density and viscosity issues, the oil was blended into a 1:1 mixture with CytoSol. This latter product is described by its formulator (CytoCulture International, Inc., Point Richmond, CA, USA) as a “biosolvent formulation based on vegetable oil methyl esters in combination with bioremediation enhancers” commonly used as a shoreline cleaner. In addition, this shoreline cleaner was one of two products tested in the same oil-to-product ratio in our meso-scale study (Page et al., 2000). 2.2 Beaker Experiment A series of 1L beakers were filled with deionized water in preparation for replicate applications (n = 2-4) of known volumes of oil mixture to their surface. Seven loadings of oil mixture were chosen to cover a one order of magnitude range in mixture mass per unit area (3 to 40 mg/cm). The upper limit was also chosen to cover that highest values expected to be used in slick experiments (~30 mg/cm). The oil/CytoSol mixture spread rapidly to form a uniform layer over the whole water surface of the beakers. Sampling of the water surface (Figure 1) involved placing a C-18 solid-phase extraction disk (SPE Empore‰, Filtration Products, St. Paul, MN) on a fritted funnel that was attached to a small pump. A slight vacuum was applied to hold the disk in place while sampling the slick. The disk was carefully placed on the oiled surface, and then removed quickly. The disks were then stored in 4-ounce jars, and refrigerated until processing. Proceedings of the 23 Arctic Marine Oil Spill Program Meeting, Vancouver, Canada. Vol. 1., 59-68 ______________________________________________________________________________ Figure 1. Sampling Procedure during Beaker Experiment. 2.3 Wave Tank Experiment Approximately two liters of a 1:1 oil/CytoSol mixture was prepared and spilled on the water surface of a meso-scale wave tank located at the Shoreline Environmental Research Facility (SERF) in Corpus Christi, Texas. A more detailed discussion of the wave tanks available at SERF is presented by Kitchen et al. (1997) and companion papers in these proceedings (Fuller et al., 2000; Page et al., 2000). Briefly, the oil mixture was introduced in the middle of the wave tank and the surface slick was contained within a 9 m area using “air booms” (industrial fans) at both ends of the tank (Figure 2). Sampling of the surface (n = 12) involved the same fritted funnel/pump procedure developed initially for the Beaker Experiment. During the wave tank Proceedings of the 23 Arctic Marine Oil Spill Program Meeting, Vancouver, Canada. Vol. 1., 59-68 ______________________________________________________________________________ experiment, eight SPE disks were sampled in the fuller, thicker portion of the slick and four SPE disks were used to collect oil from the thinner, filmy edge of the slick (fringe). Each disk was then stored separately in a 4-ounce jar, and refrigerated until processing. Figure 2. Wave Tank with Air Booms. 2.4 Analytical Methods The SPE disks were extracted either by Accelerated Solvent Extraction (ASE, Dionex Corp., Salt Lake City, UT) according to the method of Bauguss (1997) and using dichloromethane (DCM) as the solvent, and/or by sonicating three time the disks in 25 ml of warm DCM. The DCM extracts were reduced by evaporative concentration (TurboVap II Concentration Workstation, Zymark Corporation, Hopkinton, MA), reconstituted to a final volume of 5-10 ml, and then refrigerated until analysis. All samples were preserved in pre-cleaned glass container (EPA grade) to insure no residual hydrocarbon contamination. All solvents were HPLC-grade or better. Total Extractable Materials (TEM) were determined gravimetrically using replicate aliquots of the DCM extracts according to standard gravimetric Oil and Grease methods (USEPA, 1983, 1986) and slight modifications by Mills et al. (1999). Briefly, a 100-250 _l aliquot of concentrated extract was added to a tared pre-combusted glass-fiber filter, the solvent evaporated, and the filter weighed. Total Petroleum Hydrocarbon (TPH) concentrations were acquired by GC-MS analysis (EPA SW846, modified method 8270b) by injecting a 1 _l aliquot of DCM extract into a Hewlett-Packard (HP) 5890 Series II gas chromatograph (GC) interfaced to a 5972 mass selective detector (MS) and operated using HP MS ChemStation software (HewlettPackard Corporation, Palo Alto, CA, USA). Total Petroleum Hydrocarbon (TPH) concentrations are defined as the sum of the total resolved hydrocarbons (including n-C10 through n-C34) and the unresolved complex mixture. To insure the accuracy and precision of the method, Quality Proceedings of the 23 Arctic Marine Oil Spill Program Meeting, Vancouver, Canada. Vol. 1., 59-68 ______________________________________________________________________________ Assurance/Quality Control (QA/QC) measures were incorporated in the method. During extractions, blank extraction samples, duplicate samples, and standard reference materials (SRMs) were processed along with the samples of interest. The GC-MS system was calibrated with a seven-point curve and based on relative response factors (RRF) derived from target analyte standards or nearest homologues. More details of the analytical technique for the determination of TPH have been oulined in Mills et al. (1999). 3.0 Results We first evaluated the recoveries of oil mixture by adding known amounts of oil (~240 mg; n = 3) on SPE disks and subsequently extracting these disks under sonication. Based on TEM and TPH quantification methods, the recovery efficiency of oil was 95±6% and 98±14%, respectively, indicating that oil was recovered with high efficiency from the pads. When we tested sonication vs. ASE as extraction procedures on a series of oil concentrations adsorbed to SPE disks, no significant difference was observed for both TEM and TPH values. Although these results indicate that both extraction methods can be used to extract oil materials from SPE disks, each provide singular advantages and disadvantages. The sonication method does not require highend and costly equipment but is more time-consuming and uses more solvent. On the other hand, the ASE method uses less solvent, is more automated, but requires more expensive equipment. Using both TEM and TPH to quantify recoveries, we observed that the sampling of oil mixture per unit area of the SPE disks was strongly correlated to the amount of oil mixture per unit area on the beakers with a sampling efficiency of 1:1 and an average variability for replicate samples of ~7% (Figure 3a-b).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Solid Phase Extraction of Amount Cu(II) Using C18 Disks Modified Schiff Base-Chitosan Grafted Multiwalled Carbon Nanotubes

A novel and selective method for the fast determination of trace amounts of Cu(II) ions in water samples has been developed. The procedure is based on the selective formation of Cu(II) at optimum pH by elution with organic eluents and determination by flame atomic absorption spectrometry. The method is based on complex formation on the surface of the ENVI-18 DISKTM disks modified Schiff base-ch...

متن کامل

Solid Phase Extraction of Amount Cu(II) Using C18 Disks Modified Schiff Base-Chitosan Grafted Multiwalled Carbon Nanotubes

A novel and selective method for the fast determination of trace amounts of Cu(II) ions in water samples has been developed. The procedure is based on the selective formation of Cu(II) at optimum pH by elution with organic eluents and determination by flame atomic absorption spectrometry. The method is based on complex formation on the surface of the ENVI-18 DISKTM disks modified Schiff base-ch...

متن کامل

Determination of Some Polycyclic Aromatic Hydrocarbons in the Caspian Seawater by HPLC Following Preconcentration with Solid-Phase Extraction

A solid-phase extraction (SPE) method for sample clean-up and preconcentration followed by reversed-phase high-performance liquid chromatography (RP-HPLC) with uv detection is reported for determination of polycyclic aromatic hydrocarbons (PAHs) in the caspian seawater. A good resolution was obtained using acetonitrile:water (40:60) as mobile-phase for separation of these compounds. The eff...

متن کامل

Review of preconcentration and solid phase extraction for the determination of trace Lead

Spectrometric techniques for the analysis of trace lead have developed rapidly due to the increasing need for accurate measurements at extremely low levels of this element in diverse matrices. This review covers separation and preconcentration procedures, and considers the features of the application with several spectrometric techniques. The use of an appropriate sample handling technique is a...

متن کامل

Review of preconcentration and solid phase extraction for the determination of trace Lead

Spectrometric techniques for the analysis of trace lead have developed rapidly due to the increasing need for accurate measurements at extremely low levels of this element in diverse matrices. This review covers separation and preconcentration procedures, and considers the features of the application with several spectrometric techniques. The use of an appropriate sample handling technique is a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002