Steady-state force-velocity relation in human multi-joint movement determined with force clamp analysis.
نویسندگان
چکیده
To study the force-velocity characteristics of human knee-hip extension movement, a dynamometer, in which force was controlled by a servo system, was developed. Seated subjects pressed either bilaterally or unilaterally a force plate, a horizontal position of which was servo-controlled so as to equalize the measured force and a force command generated by a computer at a time resolution of 2 ms (force clamp). The force command was based on the relation between maximum isometric force and foot position within the range between 70% and 90% of "leg length" (LL: longitudinal distance between the sole of the foot and the hip joint), so that the same force relative to the maximum isometric force was consistently applied regardless of the foot position. By regulating the force according to this function, the force-velocity relation was determined. The force-velocity relation obtained was described by a linear function (n=17, r=-0.986 for 80% LL, r=-0.968 for 85% LL) within a range of force between 0.1 and 0.8F(0) (maximum isometric force). The maximum force extrapolated from the linear regression (F(max)) coincided with F(0) (n=17, F(0)/F(max)=1.00+/-0.09 for 80% LL and 1.00+/-0.20 for 85% LL). Also, the velocity at zero force (V(max)) was obtained from the extrapolation. When compared to the bilateral movements, unilateral movements gave rise to a smaller F(max) but the same V(max), suggesting that V(max) is independent of force and therefore represents the proper unloaded velocity. It is suggested that some neural mechanisms may be involved in the force-velocity relation of the knee-hip extension movement, and make it exhibit a linear appearance rather than a hyperbola.
منابع مشابه
Optimizing control motion of a human arm With PSO-PID controller
Functional electrical stimulation (FES) is the most commonly used system for restoring function after spinal cord injury (SCI). In this study, we used a model consists of a joint, two links with one degree of freedom, and two muscles as flexor and extensor of the joint, which simulated in MATLAB using SimMechanics and Simulink Toolboxes. The muscle model is based on Zajac musculotendon actuator...
متن کاملApplication of the method of multiple scales for nonlinear vibration analysis of mechanical systems with dry and lubricated clearance joints
In this study, the method of multiple scales is used to perform a nonlinear vibration analysis of a mechanical system in two cases; with dry and lubricated clearance joints. In the dry contact case, the Lankarani-Nikravesh model is used to represent the contact force between the joined bodies. The surface elasticity is modeled as a nonlinear spring-damper element. Primary resonance is discussed...
متن کاملبررسی خواص ویسکوالاستیک گشتاور غیر فعال در حرکت اکستنشن و فلکشن مفصل آرنج
Background: Many researches have been conducted inorder to explore the ingredients of joint impairements like muscle spasticity and joint rigidity in which mechanical viscoelastic properties have been quantified during the joint movement. The aim of this study was to explore passive viscose and elastic properties at flexion and extension of the human elbow joint and to determine a mat...
متن کاملEffect of Fatigue on Ground Reaction Force Variables During Single-leg Landing in Athletes With the History of Anterior Cruciate Ligament Injury
Introduction: Since people experience fatigue after anterior cruciate ligament injury during exercises, it is important to understand how fatigue affects the biomechanical movement patterns. Therefore, this study aimed to investigate the effect of fatigue on ground reaction force variables during single-leg landing in athletes with a history of an anterior cruciate ligament spr...
متن کاملOnset of mechanical activation of mammalian heart muscle in calcium- and strontium-containing solutions.
The time course of the relationship between force, shortening velocity, and length during shortening was examined in mammalian heart muscle in calcium (Ca)-containing solutions and solutions with strontium (Sr) substituted for Ca by imposing load clamps of various amplitudes at various times during external shortening. The onset of this force-velocity-length relationship was measured by abruptl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomechanics
دوره 40 7 شماره
صفحات -
تاریخ انتشار 2007