The air gap sign.

نویسندگان

  • Edmund Kenneth Kerut
  • Curtis Hannawalt
  • Charles T Everson
  • Navin C Nanda
چکیده

An elderly female aspirated a donut and subsequently had loss of consciousness and cardiopulmonary arrest. Family members performed chest compressions until emergency medical services arrived and resuscitated the patient with an adequate heart rate and blood pressure. On hospital admission, the patient was nonresponsive on a mechanical ventilator. Cardiac auscultation revealed distant heart tones, but no rub or mediastinal crunch was heard. The admission chest x-ray revealed a normal cardiac silhouette, but the presence of a pneumopericardium (Fig. 1). Two-dimensional echocardiography was best imaged from the subcostal window. Loss of ultrasound signal was

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correlated Effect of Air Gap and PVP Concentration on the Structure and Performance of PVDF Ultrafiltration Hollow Fiber Membrane

Polyvinylidene fluoride/polyvinylpyrrolidone (PVDF/PVP) hollow fiber membranes were fabricated by dry-jet wet-spinning process. The correlated effects of the air gap length and PVP concentration ((1) the air gap length effect at the low and high PVP concentration in the dope solutions, as well as (2) the effect of the PVP concentration at the same air gap length) on the cross-section structure ...

متن کامل

A Capacitive Fed Microstrip Patch Antenna with Air Gap for Wideband Applications (RESEARCH NOTE)

In this paper a microstrip antenna on a suspended substrate with capacitive feed is presented. capacitive feed is created by a slot within the rectangular patch around the feed point. The proposed antenna exhibits a much higher impedance bandwidth of about 47% (S11 < −10 dB). Effects of key design parameters such as the air gap between the substrate and the ground plane, the gap width between r...

متن کامل

Influence of Air-Gap Length on CO2 Stripping from Diethanolamine Solution and Water Performance of Surface Modified PVDF Hollow Fiber Membrane Contactor

Surface Modifying Macromolecule (SMM) blended PVDF hollow fibers (HFs) were spun at different air-gaps (o to 20 cm) and used for CO2 stripping from aqueous DEA solution and water. The manufactured fibers were first subjected to various characterization tests such as contact angle and critical water entry pressure measurement to evaluate the HF hydrophobicity and wetting resistanc...

متن کامل

Diagnosis of Different Types of Air-Gap Eccentricity Fault in Switched Reluctance Motors Using Transient Finite Element Method

This paper presents a method for diagnosis of eccentricity fault in a switched-reluctance motor (SRM) during offline and standstill modes. In this method, the fault signature is differential induced voltage (DIV) achieved by injecting diagnostic pulses to the motor windings. It will be demonstrated by means of results that there is a correlation between differential induced voltage and eccentri...

متن کامل

A Simple Analytic Method to Model and Detect Non-Uniform Air-Gaps in Synchronous Generators

The air-gap of electrical machines may become non-uniform due to low accuracy of the manufacturing machinery, in assembling processes, or by aging. Detection and monitoring of this phenomenon is very important and of interest. There are several methods to model non-uniform air-gaps and to detect them by monitoring systems. One of the most widely used methods is by the analysis of the line curre...

متن کامل

Design and Construction of a Sensitive Capasitive Sensor System (RESEARCH NOTE)

Design and construction of a capacitor sensor with a precise readout system are described in this paper. A variable air-gap capacitive transducer was constructed and for signalmeasurement a successful attempt was made to exploit the capacitance changes in terms of the phase angle of the detected signal. The reported setup makes it possible to detect capacitance changes of the order of 2.5 fF in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Echocardiography

دوره 31 3  شماره 

صفحات  -

تاریخ انتشار 2014