Are terminally threaded guide pins from cannulated screw systems dangerous?

نویسندگان

  • Walker Flannery
  • Joshua Balts
  • James J McCarthy
  • Jeffrey Swick
  • Kenneth J Noonan
  • Jeremy Olson
چکیده

Threaded and smooth pins are often used in orthopedic surgery. Although uncommon, injury to the soft tissues can and do occur, including nerve or vessel injury from aberrant pin placement. The purpose of this study was to compare the risk of nerve injury from threaded pins versus smooth guide pins due to: (1) past-point-drilling of the pin, or (2) entanglement of the pin with soft tissue. Past-point drilling was tested by a blindfolded participant drilling a 1.6-mm guide pin (terminally threaded or smooth) through a porcine femur until they felt they had drilled through the second cortex. The distance over-drilled was measured in millimeters. Twenty trials were randomly completed, 10 with each pin type. Entanglement of soft tissue was tested by placing the terminal portion of the guide pin on the nerve. Two drilling positions were tested: (1) drilling at 90° and (2) parallel to the nerve. The drill was run for 1 second and assessed for entanglement and magnitude of entanglement (measured in millimeters of nerve wrapped by the pin). Sixty trials were completed, 15 with each pin type, and in each of the 2 positions. The average past-point drilling depths were 4.6 and 16.9 mm for the smooth and threaded pins, respectively (P<.05). The mean nerve overwrapping was 0.45 and 4.7 mm, for the smooth and threaded pins, respectively (P<.05), drilled at 90° and 0.15 and 0.92 mm, respectively (P<.05) in the parallel position. In 13 of 60 trials with the smooth pin and 50 of 60 trials with the threaded pin, wrapping was observed (P<.05). This study demonstrates that it is difficult to determine by feel when the threaded pin has drilled through the second cortex of the bone, in contrast to the smooth pin. Furthermore, soft tissue entanglement is more likely and to a greater magnitude with threaded pins than with smooth.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Arthroscopic Bony Bankart Repair Using Double-Threaded Headless Screw: A Case Report

We present a case of arthroscopic fixation for bony Bankart lesion using a double-threaded cannulated screw. A 39-year-old man sustained a left shoulder injury from a motorcycle accident. Radiographs showed bony Bankart lesion and CT revealed 40% defect of glenoid articular surface. Arthroscopic fixation was performed using double-threaded cannulated screw after the bony fragment was reduced by...

متن کامل

Biomechanical comparison of first metatarsophalangeal joint arthrodeses using triple-threaded headless screws versus partially threaded lag screws.

BACKGROUND Triple-threaded, cannulated headless screws of varying thread diameters and pitch are designed to maintain thread length across the arthrodesis plane, provide joint compression, and reduce countersinking. This study tested the biomechanical fixation strength of conventional partially threaded lag screws compared to triple-threaded headless screws in first metatarsophalangeal joint ar...

متن کامل

Self-designed femoral neck guide pin locator for femoral neck fractures.

Closed reduction and fixation with 3 cannulated screws is a widely accepted surgery for the treatment of femoral neck fractures. However, how to obtain optimal screw placement remains unclear. In the current study, the authors designed a guide pin positioning system for femoral neck fracture cannulated screw fixation and examined its application value by comparing it with freehand guide needle ...

متن کامل

Epiphysiodesis Screw Bending.

Percutaneous epiphysiodesis using transphyseal screws is a common method for treatment of limb length discrepancy and angular deformity. The authors report 3 cases of a previously unreported complication following treatment with percutaneous epiphysiodesis using transphyseal screws: bending of the transphyseal screw. In each case, this rare complication was associated with difficult removal of ...

متن کامل

Failure of asnis iii 5.0 mm cannulated screw: a case report

We describe a case of an ASNIS III 5.0 mm partially threaded cannulated screw unthreading itself as it was being inserted during fracture fixation of a humerus. The majority of complications associated with cannulated screws involve breaking of the screw, as opposed to unthreading. We believe that the self tapping design of the screw, in combination with the cannulated design, creates a potenti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Orthopedics

دوره 34 8  شماره 

صفحات  -

تاریخ انتشار 2011