Electrochemical analysis of chloramphenicol using boron-doped diamond electrode applied to a flow-injection system.

نویسندگان

  • Suchada Chuanuwatanakul
  • Orawon Chailapakul
  • Shoji Motomizu
چکیده

The electrochemical properties of chloramphenicol at a boron-doped diamond thin-film (BDD) electrode were studied using cyclic voltammetry. The highest current response of chloramphenicol was obtained with phosphate buffer, pH 6 (0.1 M) in 1% ethanol. The relationship between the concentration of chloramphenicol and the current response was linear over the range of 0.1-10 mM (R2=0.9990). The amount of chloramphenicol was analyzed by flow-injection analysis. A thin-layer flow cell equipped with a BDD electrode was used as an amperometric detector, and experiments were carried out at -0.7 V (vs. Ag/AgCl). The linear relationship between the current response and the concentration of chloramphenicol in the range of 0.1-50 microM (R2=0.9948) and the limit of detection of 0.03 microM (S/N=3) were obtained. This method has been successfully applied to the determination of chloramphenicol in sterile eye drops and milk sample by the standard addition method. The average recoveries of chloramphenicol in eye drops were 98.0%, and the average recoveries of chloramphenicol from spiked milk were 93.9-103%.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Studies on Novel Flow - Based Electrochemical Methods for Trace and Ultratrace Analysis of Some Harmful Substances

55 This works describes the development of novel flow-based electrochemical methods and their application to the determination of some harmful substances: antibiotics (lincomycin, chloramphenicol), antibacterial agents (sulfonamides), and heavy metals (lead, cadmium and zinc), in pharmaceuticals, foods, and drinking water. The electroanalysis of lincomycin was investigated using boron-doped dia...

متن کامل

Electroanalysis of tetracycline using nickel-implanted boron-doped diamond thin film electrode applied to flow injection system.

The electrochemical analysis of tetracycline was investigated using nickel-implanted boron-doped diamond thin film electrode by cyclic voltammetry and amperometry with a flow injection system. Cyclic voltammetry was used to study the electrochemical oxidation of tetracycline. Comparison experiments were carried out using as-deposited boron-doped diamond thin film electrode (BDD). Nickel-implant...

متن کامل

Feedback-amplified electrochemical dual-plate boron-doped diamond microtrench detector for flow injection analysis

An electrochemical flow cell with a boron-doped diamond dual-plate microtrench electrode has been developed and demonstrated for hydroquinone flow injection electroanalysis in phosphate buffer pH 7. Using the electrochemical generator-collector feedback detector improves the sensitivity by one order of magnitude (when compared to a single working electrode detector). The diffusion process is sw...

متن کامل

Electrochemical detection of sugar-related compounds using boron-doped diamond electrodes.

Electrochemical detection of sugar-related compounds was conducted using a boron-doped diamond (BDD) electrode as a detector for flow-injection analysis (FIA). Sugar-related compounds oxidize at high applied potentials, for which the BDD electrode is suitable for electrochemical measurements. Conditions for an FIA system with a BDD detector were optimized, and the following detection limits wer...

متن کامل

Continuous and selective measurement of oxytocin and vasopressin using boron-doped diamond electrodes

The electrochemical detection of oxytocin using boron-doped diamond (BDD) electrodes was studied. Cyclic voltammetry of oxytocin in a phosphate buffer solution exhibits an oxidation peak at +0.7 V (vs. Ag/AgCl), which is attributable to oxidation of the phenolic group in the tyrosyl moiety. Furthermore, the linearity of the current peaks obtained in flow injection analysis (FIA) using BDD micro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 24 4  شماره 

صفحات  -

تاریخ انتشار 2008