The AneuRx stent graft: four-year results and worldwide experience 2000.
نویسندگان
چکیده
OBJECTIVE The objective was to review the current results of endovascular abdominal aortic aneurysm repair with the AneuRx stent graft and to determine the effectiveness of the device in achieving the primary objective of preventing aneurysm rupture. METHODS The outcome of all patients treated during the past 4 years in the U.S. AneuRx clinical trial was determined, and the worldwide clinical experience was reviewed. RESULTS A total of 1192 patients were treated with the AneuRx stent graft during all phases of the U.S. Clinical Trial from June 1996 to November 1999, with follow-up extending to June 2000. Ten (0.8%) patients have had aneurysm rupture, with most ruptures (n = 6) occurring in 174 (3.4%) patients treated with an early stiff bifurcation stent graft design used in phase I and in the initial stages of phase II. Since the current, flexible, segmented bifurcation stent graft design was introduced, four (0.4%) ruptures have occurred among 1018 patients treated. Of these, one was during implantation, two were placed too far below the renal arteries, and one patient refused treatment of a type I endoleak. Kaplan-Meier analysis of all 1192 patients treated with the AneuRx stent graft including both stent graft designs revealed the patient survival rate to be 93% at 1 year, 88% at 2 years, and 86% at 3 years, freedom from conversion to open repair to be 98% at 1 year, 97% at 2 years, and 93% at 3 years, and freedom from secondary procedure to be 94% at 1 year, 92% at 2 years, and 88% at 3 years. Freedom from aneurysm rupture with the commercially available segmented bifurcation stent graft was 99.7% at 1 year, 99.5% at 2 years, and 99.5% at 3 years. The presence or absence of endoleak on contrast computed tomography scanning after stent graft placement was not found to be a significant predictor of long-term outcome measures. Worldwide experience with the AneuRx device now approaches 10,000 patients. CONCLUSIONS Endovascular management of abdominal aortic aneurysms with the AneuRx stent graft has markedly reduced the risk of aneurysm rupture while eliminating the need for open aneurysm surgery in 98% of patients at 1 year and 93% of patients at 3 years. The device was effective in preventing aneurysm rupture in 99.5% of patients over a 3-year period. The overall patient survival rate was 93% at 1 year and 86% at 3 years.
منابع مشابه
Endograft Migration: Incidence, Causes, and Clinical Significance
Endovascular device migration is approximately 2% at 1 year using each of the Food and Drug Administration-approved devices (Medtronic AneuRx, Gore Excluder, Cook Zenith). In this report, we review the incidence, causes, and clinical importance of endograft migration over a 5-year period after endovascular aneurysm repair with the AneuRx stent graft. In a multicenter United States clinical tria...
متن کاملAneurysm rupture after endovascular repair using the AneuRx stent graft.
OBJECTIVE The purpose of this study was to determine the cause and frequency of aneurysm rupture after endovascular aneurysm repair. METHODS We reviewed each patient who sustained aneurysm rupture among all patients enrolled for endovascular aortic aneurysm repair in phases I, II, and III of the US AneuRx Multicenter Clinical Trial from June 1996 through October 1999. RESULTS A total of 106...
متن کاملThe US AneuRx Clinical Trial: 6-year clinical update 2002.
A total of 1193 patients with infrarenal abdominal aortic aneurysms were treated with the AneuRx Stent Graft System at 19 US investigational centers from 1996 to 1999. This report summarizes clinical data collected and analyzed as of August 28, 2002. There have been 10 late (>30 days) aneurysm ruptures, 8 late (>30 days) aneurysm-related deaths, and 38 late (>30 days) surgical conversions, incl...
متن کاملPreliminary results of endovascular abdominal aortic aneurysm exclusion with the AneuRx stent-graft.
OBJECTIVES This study evaluated the clinical effectiveness of the Medtronic AneuRx stent-graft in patients with infrarenal abdominal aortic aneurysms (AAAs) who were treated in an endovascular suite. BACKGROUND The use of endovascular stent-graft prosthesis for the treatment of AAAs is receiving increasing attention as an alternative to standard surgical repair. Endovascular treatment of AAAs...
متن کاملEndoleak as a predictor of outcome after endovascular aneurysm repair: AneuRx multicenter clinical trial.
OBJECTIVE The purpose of this study was to determine whether evidence of blood flow in the aneurysm sac (endoleak) is a meaningful predictor of clinical outcome after successful endovascular aneurysm repair. METHODS We reviewed all patients in Phase II of the AneuRx Multicenter Clinical Trial with successful stent graft implantation and predischarge contrast computed tomographic (CT) imaging....
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of vascular surgery
دوره 33 2 Suppl شماره
صفحات -
تاریخ انتشار 2001