Novel anterior cruciate ligament graft fixation device reduces slippage

نویسندگان

  • Mandi J Lopez
  • Allen Borne
  • W Todd Monroe
  • Prakash Bommala
  • Laura Kelly
  • Nan Zhang
چکیده

Clinically significant laxity occurs in 10%-30% of knees after anterior cruciate ligament reconstruction. Graft slippage and tension loss at the hamstring graft tibial fixation site during and after reconstruction surgery contribute to postoperative joint laxity and are detrimental to long-term knee stability and graft properties. Limiting graft slippage will reduce associated complications. We sought to compare the in vitro mechanical properties and in vivo joint stabilization, postoperative limb use, and graft incorporation of the novel GraftGrab™ (GG) device designed to reduce hamstring graft tibial fixation slippage with the commercially available bioabsorbable Bio-Post™ and spiked washer (BP). Mechanical testing was performed on canine tibia-hamstring graft constructs to quantify initial fixation properties. In vivo joint stabilization, postoperative limb use and graft incorporation of hamstring graft reconstructions were determined in a canine model. Outcomes included tibial translation and ground reaction forces preoperatively and 4 and 8 weeks postoperatively, three-dimensional graft and bone tunnel dimensions at the latter two time points, and graft-bone microstructure, as well as mechanical properties 8 weeks after implantation. Immediately after fixation, all grafts slipped from the BP constructs versus about 30% of GG constructs. In vivo limb use remained low, and tibial translation increased with time in the BP cohort. These results together confirm that initial graft slippage is lower with GG versus BP extracortical hamstring graft tibial fixation. In addition, postoperative recovery and joint stability are more consistent with the GG. This information supports the GG as an alternative to extracortical tibial hamstring graft fixation that has procedural advantages over current implants and reduces graft failure from slippage.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Compaction of a bone dowel in the tibial tunnel improves the fixation stiffness of a soft tissue anterior cruciate ligament graft: an in vitro study in calf tibia.

BACKGROUND Despite increasing attention on fixation of a soft tissue anterior cruciate ligament graft in the tibia, there have been no studies on the use of a bone dowel as a joint line fixation device for promoting fixation properties, especially stiffness at the time of implantation. PURPOSE To determine whether compacting a bone dowel into the tibial tunnel improves fixation stiffness, yie...

متن کامل

The WasherLoc and Bone Dowel: A Rigid, Slippage-Resistant Tibial Fixation Device for a Soft Tissue Anterior Cruciate Ligament Graft

The WasherLoc is a tibial fixation device for soft tissue anterior cruciate ligament (ACL) reconstruction that combines superior fixation properties (945 N strength, 507 N/mm stiffness, and high resistance to slippage) with a simple surgical technique. The WasherLoc is a washer with 13 short spikes that penetrate the soft tissue ACL graft in multiple locations and 4 long peripheral spikes that ...

متن کامل

One-Year Serial Follow-up Magnetic Resonance Imaging Study of RigidFix for Femoral Fixation in Anterior Cruciate Ligament Reconstruction

Purpose To assess graft slippage at the site of femoral fixation by follow-up magnetic resonance imaging (MRI) after anterior cruciate ligament (ACL) reconstruction with a four-strand autogenous hamstring tendon using RigidFix (DePuy Mitek). Materials and Methods Twenty-one subjects diagnosed with ACL rupture underwent ACL reconstruction using hamstring autograft with the transtibial techniqu...

متن کامل

Anterior laxity, slippage, and recovery of function in the first year after tibialis allograft anterior cruciate ligament reconstruction.

BACKGROUND The increase in anterior laxity and slippage is greater with metal interference screw fixation of a hamstring anterior cruciate ligament (ACL) graft than a bone-patellar tendon-bone graft. HYPOTHESIS When slippage-resistant fixation is used with a soft tissue graft, early recovery of function does not result in a clinically important increase in anterior laxity and slippage STUDY...

متن کامل

Multistranded hamstring tendon graft fixation with a central four-quadrant or a standard tibial interference screw for anterior cruciate ligament reconstruction.

BACKGROUND Tibial fixation of hamstring tendon grafts has been the weak link in anterior cruciate ligament reconstruction. HYPOTHESIS Use of a central four-quadrant sleeve and screw provides superior fixation when compared with standard interference screw fixation. STUDY DESIGN Controlled laboratory study. METHODS In eight pairs of cadaveric knees each anterior cruciate ligament was recon...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2013