Sample depletion of the matrix-assisted laser desorption process monitored using radionuclide detection.

نویسندگان

  • Jason S Page
  • Jonathan V Sweedler
چکیده

To investigate analyte consumption during the laser desorption process, matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS) is combined with radionuclide detection. Radionuclide detection provides highly sensitive and quantitative information on the amount of radiolabeled analytes in a MALDI MS sample spot. 14C-Labeled cytochrome c is deposited with 2,5-dihydroxybenzoic acid in 10-nL volume spots. By comparing radioactivity levels of the labeled cytochrome c both before and after spectral acquisition, the reduction in labeled analyte molecules on the target allows monitoring of the moles of desorbed sample. Through a depletion study on this sample, the amount of analyte consumed for MALDI time-of-flight spectral acquisition and the average number of molecules desorbed per laser ablation are determined. When [14C]-cytochrome c is no longer detected by MALDI MS, approximately 70% of the original analyte remains in the sample spots. Redissolving the spots produced further desorption, indicating that the analyte before dissolution was in a physical environment that did not facilitate the desorption process. As a technique with a response that does not depend on the environment of the analyte, radionuclide detection allows characterization of mass-limited sampling methods to better understand the MALDI process.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigations of electrospray sample deposition for polymer MALDI mass spectrometry.

In the interest of a more thorough understanding of the relationship between sample deposition technique and the quality of data obtained using matrix-assisted laser desorption/ionization (MALDI) mass spectrometry, details of the electrospray (ES) process of sample deposition are investigated using a number of techniques. Sample morphology was observed with scanning electron microscopy (SEM) an...

متن کامل

On-probe sample pretreatment for direct analysis of lipids in gram-positive bacterial cells by matrix-assisted laser desorption ionization mass spectrometry.

On-probe sample pretreatment using trifluoroacetic acid as an additional reagent enabled the direct detection of phospholipids in whole bacteria by means of matrix-assisted laser desorption ionization mass spectrometry for not only gram-negative organisms but also gram-positive ones with a thicker peptidoglycan layer.

متن کامل

Functionalized nanoparticles and nanostructured surfaces for surface-assisted laser desorption/ionization mass spectrometry.

Surface-assisted laser desorption/ionization time-of-flight mass spectrometry (SALDI-TOF-MS) using nanoparticles (NPs) and nanostructured surfaces as the LDI-assisting nanomaterials is a soft ionization technique that features minimal fragmentation of analytes. As compared to traditional matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) using organic ma...

متن کامل

Sample preparation in matrix-assisted laser desorption/ionization mass spectrometry of whole bacterial cells and the detection of high mass (>20 kDa) proteins.

Three sample preparation strategies commonly employed in matrix-assisted laser desorption/ionization mass spectrometry (MALDI-TOFMS) of whole bacterial cells were investigated for the detection of high mass signals; these included the dried droplet, the seed-layer/two-layer, and the bottom-layer methods. Different sample preparation approaches favoured the detection of high- or low-mass protein...

متن کامل

Monitoring enzyme reaction and screening enzyme inhibitor based on MALDI-TOF-MS platform with a matrix of oxidized carbon nanotubes.

A matrix assisted laser desorption/ionization time-of-flight mass spectrometry platform for quantitatively monitoring enzyme activity and screening enzyme inhibitors has been demonstrated. The described method employs a new matrix of oxidized carbon nanotubes. Compared with the traditional fluorescence approach, this label-free method has the advantage of directly identifying the substrates and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical chemistry

دوره 74 24  شماره 

صفحات  -

تاریخ انتشار 2002