Evaluation of various rapid agglutination methods for the identification of Staphylococcus aureus.

نویسندگان

  • J S Baker
  • M A Bormann
  • D H Boudreau
چکیده

A latex agglutination test (SeroSTAT Staph; Scott Laboratories, Fiskeville, R.I.) and two hemagglutination tests (Staphyloslide; BBL Microbiology Systems, Cockeysville, Md.; and Hemastaph; Remel, Lenexa, Kans.) were compared with the slide coagulase (SC) and tube coagulase (TC) tests at room temperature (22 to 25 degrees C) and at 37 degrees C for the rapid identification of Staphylococcus aureus. A total of 380 clinical strains of staphylococci were tested. The TC test performed at room temperature yielded the largest number of TC-positive results (n = 239), and based on this observation 239 organisms were classified as S. aureus and 141 were classified as non-S. aureus. The SC, TC (37 degrees C), SeroSTAT Staph, Staphyloslide, and Hemastaph tests correctly identified 210 (87.9%), 221 (92.5%), 238 (99.6%), 239 (100%), and 236 (98.7%) of the S. aureus isolates, respectively. Of the S. aureus isolates that were TC positive at room temperature 68% required 24 h of incubation before coagulase production was detected. There was one false-negative SeroSTAT Staph result and one false-negative Hemastaph result. The Staphyloslide test yielded two noninterpretable results (both organisms were later confirmed as non-S. aureus), whereas there were six noninterpretable results recorded with the Hemastaph test (four organisms were classified as non-S. aureus, and two were classified as S. aureus). The SeroSTAT Staph, Staphyloslide, and Hemastaph tests were all more sensitive than the conventional SC and TC (37 degrees C) tests and were considerably more rapid than the TC test at either temperature.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Efficacies of rapid agglutination tests for identification of methicillin-resistant staphylococcal strains as Staphylococcus aureus.

Four commercially available rapid agglutination tests for the identification of Staphylococcus aureus were compared with the tube coagulase test for the identification of 300 methicillin-resistant isolates of staphylococci. Isolates tested included 207 methicillin-resistant S. aureus and 93 coagulase-negative staphylococci, collected from five medical centers. Strain variability was documented ...

متن کامل

Evaluation of rapid coagulase methods for the identification of Staphylococcus aureus.

Four rapid latex agglutination assays, StaphAurex (Wellcome Diagnostics, Research Triangle Park, N.C.), Bacto Staph (Difco Laboratories, Detroit, Mich.), SeroSTAT (Scott Laboratories, Inc., Fiskeville, R.I.), Veri-Staph (Zeus Technologies, Raritan, N.J.), and two hemagglutination tests, Staphyloslide (BBL Microbiology Systems, Cockeysville, Md.) and Hemastaph (Remel, Lenexa, Kans.), were compar...

متن کامل

Evaluation of a rapid culture-based screening test for detection of methicillin resistant Staphylococcus aureus.

The performance of a culture based assay, BacLite Rapid MRSA for the rapid detection (5 hours) of methicillin resistant Staphylococcus aureus (MRSA) from specimens (n = 377) obtained from nares, throat, wounds and perineum was investigated. Compared to culture based reference methods (chromogenic MRSA ID (bioMerieux)), selective enrichment broth, PBP2' latex agglutination (Oxoid) and VITEK 2 id...

متن کامل

Evaluation of three commercial agglutination tests for the identification of Staphylococcus aureus.

Three commercially available rapid slide agglutination tests for the identification of Staphylococcus aureus were evaluated with 354 recent clinical isolates (165 strains of S. aureus). The test results of two latex agglutination products, SeroSTAT Staph (Scott Laboratories, Inc.) and Staphylatex (American Micro Scan), and one hemagglutination product, Staphyloslide (BBL Microbiology Systems), ...

متن کامل

Evaluation of three rapid methods for detection of methicillin resistance in Staphylococcus aureus.

The probe-based Velogene Rapid MRSA Identification Assay (ID Biomedical Corp., Vancouver, British Columbia, Canada) and the latex agglutination MRSA-Screen (Denka Seiken Co., Tokyo, Japan) were evaluated for their ability to identify methicillin-resistant Staphylococcus aureus (MRSA) and to distinguish strains of MRSA from borderline oxacillin-resistant S. aureus (BORSA; mecA-negative, oxacilli...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 21 5  شماره 

صفحات  -

تاریخ انتشار 1985