Noninvasive assessment of local pulse pressure: importance of brachial-to-radial pressure amplification.

نویسندگان

  • Francis Verbeke
  • Patrick Segers
  • Steven Heireman
  • Raymond Vanholder
  • Pascal Verdonck
  • Luc M Van Bortel
چکیده

The advocated SphygmoCor procedure uses a radial-to-aorta transfer function with calibration on brachial instead of radial artery pressure to assess the central pulse pressure. We compared these values with carotid artery pulse pressures obtained from a validated calibration method, assuming mean minus diastolic blood pressure constant throughout the large artery tree. From 44 healthy subjects (21 males; 22 to 68 years) pressure waves were obtained at the radial, brachial, and carotid artery with applanation tonometry. Using the calibration method, radial and carotid artery pressures were assessed from brachial artery waves and pressures. The effect of brachial-to-radial pulse pressure amplification, brachial pulse pressure, mean pressure, age, gender, height, body mass index, and smoking on differences between the 2 methods was assessed. Brachial artery pressure was 118+/-12/72+/-10 mm Hg. SphygmoCor central pulse pressure was 9.7+/-4.6 mm Hg lower (P<0.001) than the carotid artery pulse pressure (33.0+/-6.8 versus 42.7+/-8.9 mm Hg). The difference between the 2 methods strongly depended (P<0.001) on brachial-to-radial artery pulse pressure amplification (5.8+/-5.1 mm Hg; 12+/-11%) and less on brachial artery pulse pressure (P=0.005). After calibration of the radial pressure wave with radial instead of brachial artery pressures, the difference between SphygmoCor central pulse pressure and carotid pulse pressure decreased with 4 mm Hg. The advocated SphygmoCor procedure systematically underestimates the central pulse pressure with brachial-to-radial pulse pressure amplification as important determinant. Therefore, calibration of radial artery pressure waves on brachial artery pressures should be avoided. The underestimation of central aortic pulse pressure caused by the radial-to-aorta transfer function itself is much less than previously reported.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impact of radial artery pressure waveform calibration on estimated central pressure using a transfer function approach.

Impact of Radial Artery Pressure Waveform Calibration on Estimated Central Pressure Using a Transfer Function Approach To the Editor: It is with great interest that we have read the excellent work of McEniery et al1 on the variability of the relation between central and brachial pulse pressure (pressure amplification), assessed in 10 000 subjects. We were, however, a little surprised about the ...

متن کامل

Amplification of the pressure pulse in the upper limb in healthy, middle-aged men and women.

Central-to-peripheral amplification of the pressure pulse leads to discrepancies between central and brachial blood pressures. This amplification depends on an individual's hemodynamic and (patho)physiological characteristics. The aim of this study was to assess the magnitude and correlates of central-to-peripheral amplification in the upper limb in a healthy, middle-aged population (the Asklep...

متن کامل

Role of pulse pressure amplification in arterial hypertension: experts' opinion and review of the data.

Arterial hypertension is a major modifiable cardiovascular (CV) risk factor worldwide based on observational studies of brachial artery blood pressure (BP). In the latest guidelines of the European Society of Hypertension1 for the management of arterial hypertension, aortic stiffness was introduced as an index of target organ damage. Three additional cardinal features of BP were also acknowledg...

متن کامل

Flawed measurement of brachial tonometry for calculating aortic pressure?

Letters to the Editor will be published, if suitable, as space permits. They should not exceed 1000 words (typed double-spaced) in length and may be subject to editing or abridgment. The article by Segers et al 1 on aortic-radial wave transmission and amplification casts doubt on the present approach to the calculation of central aortic pressure from the radial artery tonomographic waveform; th...

متن کامل

Carotid Artery Hypertrophy and Atherosclerosis

Central blood pressure (BP) has been shown to predict cardiovascular disease clinical outcomes better than brachial BP in studies that demonstrate expected pulse pressure (PP) amplification. The likely underlying mechanism for this observation is a closer relation of central BP to preclinical cardiac and vascular disease because of its more accurate representation of loading conditions on the h...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Hypertension

دوره 46 1  شماره 

صفحات  -

تاریخ انتشار 2005