A Manual, Semi-Automated and Automated ROI Study of fMRI Hemodynamic Response

نویسندگان

  • Jing Zhang
  • Monte S. Buchsbaum
  • Kingwai Chu
  • Erin A. Hazlett
چکیده

This study is a method comparison of three region-of-interest (ROI) tracing approaches. fMRI images acquired during an event-related frequency discrimination task were used in this study. Three [(1) manual, (2) semi-automated, (3) automated] approaches were applied to generate the ROI in the caudate nucleus and extract fMRI hemodynamic response (HR) from the ROI. Less activation with weak and delayed fMRI HR in the caudate were observed in patients than controls by the 3 approaches, but the manual and automated approaches were more sensitive in detecting such fMRI abnormalities. High correlations of the HR measures were found between the manual and semi-automated ROI approaches, suggesting that the semi-automated approach could be used as an alternative to the manual approach in detecting fMRI experimental effect.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Functional MRI Preprocessing in Lesioned Brains: Manual Versus Automated Region of Interest Analysis

Functional magnetic resonance imaging (fMRI) has significant potential in the study and treatment of neurological disorders and stroke. Region of interest (ROI) analysis in such studies allows for testing of strong a priori clinical hypotheses with improved statistical power. A commonly used automated approach to ROI analysis is to spatially normalize each participant's structural brain image t...

متن کامل

Cost Function Modelling for Semi-automated SC, RTG and Automated and Semi-automated RMG Container Yard Operating Systems

This study analyses the concept of cost functions for semi-automated Straddle Carrier (SC), Rubber Tyred Gantry (RTG) and automated Rail Mounted Gantry (RMG) container yard operating cranes. It develops a generic cost based model for a pair-wise comparison, analysis and evaluation of economic efficiency and effectiveness of container yard equipment to be used for decision-making by terminal pla...

متن کامل

A Semi-Automated Algorithm for Segmentation of the Left Atrial Appendage Landing Zone: Application in Left Atrial Appendage Occlusion Procedures

Background: Mechanical occlusion of the Left atrial appendage (LAA) using a purpose-built device has emerged as an effective prophylactic treatment in patients with atrial fibrillation at risk of stroke and a contraindication for anticoagulation. A crucial step in procedural planning is the choice of the device size. This is currently based on the manual analysis of the “Device Landing Zone” fr...

متن کامل

مقایسه شمارش خودکار با شمارش دستی نوتروفیل‌ها در تشخیص پریتونیت باکتریال خود به خودی

Introduction: Spontaneous bacterial peritonitis (SBP) is a prevalent complication in the patients with cirrhosis and ascites, which leads to high intrahospital mortality. Diagnosis is made when ascetic fluid neutrophils is ≥250 cells/mm3. Manual counting of neutrophils is time-consuming, technically difficult, expensive and in many cases individual-dependent. In contrast, automated counting ...

متن کامل

Validity of Selected WBC Differentiation Flags in Sysmex XT-1800i

Background: Automatic Cell Counter devises make the CBC differential very easy and delivering the results in few second. However, the problem with this device is facing a flag requires a time-consuming microscopic review of the specimen which causes unacceptable wait times for patient as well as costs for laboratories. In this study, we calculated the validity of WBC d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Studies in health technology and informatics

دوره 192  شماره 

صفحات  -

تاریخ انتشار 2013