The temperature changes in the pulp chamber during cavity preparation with the Er:YAG laser using a very short pulse.

نویسندگان

  • Silvana Jukić Krmek
  • Ivana Miletic
  • Paris Simeon
  • Goranka Prpić Mehicić
  • Ivica Anić
  • Berislav Radisić
چکیده

OBJECTIVE The aim of this study was to examine the temperature changes in the pulp chamber during cavity preparation with the Er:YAG laser (2940 nm) with a very short pulse (VSP). MATERIALS AND METHODS Nine groups of 10 intact molars each were used. One root of each sample was amputated and a thermocouple was inserted into the chamber. Class V cavity preparation in enamel was performed, and then preparation was performed in dentine. The enamel was lased with 400, 360, and 320 mJ in contact mode using a VSP with a duration of 100 microsec. The diameter of the fiber tip was 950 microm. Frequencies of 10, 12, and 15 Hz were used, and the total time of irradiation was 10 sec. The dentine was irradiated with 340, 280, and 200 mJ at 10, 8, and 5 Hz for 7 sec. Cooling was done with a water spray (73 psi and 50 mL/min). The differences were tested by MANOVA and the Bonferroni post hoc test. RESULTS The highest rise in temperature in the pulp was achieved after enamel irradiation with 400 mJ and 15 Hz (1.99 +/- 0.28 degrees C), and the lowest was after irradiation with 320 mJ and 10 Hz (0.70 +/- 0.18 degrees C). In dentine the highest temperature increase was achieved with 340 mJ and 10 Hz (1.37 +/- 0.42 degrees C), and the lowest was with 200 mJ and 5 Hz (0.43 +/- 0.18 degrees C). Two-way analysis of both enamel and dentine showed that the influence of energy on temperature increase was stronger than that of frequency. CONCLUSION Cavity preparation with an Er:YAG laser using VSP mode in vitro did not cause significant increases in temperature in the pulp chamber of human molars.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intrapulpal temperature during preparation with the Er:YAG laser: an in vitro study.

OBJECTIVE This investigation evaluated the variation of the intrapulpal temperature when dentine was irradiated by the Er:YAG laser. BACKGROUND DATA The effect of preparation with the Er:YAG laser on the intrapulpal temperature is probably the biggest problem in using the laser for preparation of dental hard tissue. MATERIALS AND METHODS Seventy-two bovine incisors were studied that had the...

متن کامل

Thermal effects of the Er:YAG laser on a simulated dental pulp: a quantitative evaluation of the effects of a water spray.

OBJECTIVES To quantify the temperature increments in a simulated dental pulp following irradiation with an Er:YAG laser, and to compare those increments when the laser is applied with and without water spray. METHODS Two cavities were prepared on either the buccal or lingual aspect of sound extracted teeth using the laser. One cavity was prepared with water spray, the other without and the or...

متن کامل

Effects of removing adhesive from tooth surfaces by Er:YAG laser and a composite bur on enamel surface roughnessand pulp chamber temperature

BACKGROUND At the end of fixed orthodontic treatment, the remnant of adhesive should be eliminated from the tooth surface. The purpose of this study was to compare the effect of three methods of removing adhesive on enamel surface roughness, dental pulp temperature, and also on the time spent. MATERIALS AND METHODS The brackets on 90 extracted teeth were debonded using bracket removal pliers....

متن کامل

Pulpal Temperature Increase with High-speed Handpiece, Er:yag Laser and Ultrasound Tips

The aim of this study was to compare intrapulpal temperature increase produced by high-speed handpiece, Er:YAG laser and CVDentus ultrasound tips during cavity preparation. Thirty bovine mandibular incisors with an enamel/dentin thickness of 4 mm at buccal surface had their roots amputated and were allocated to the following groups (n=10): Group I- high-speed handpiece; Group II- noncontact Er:...

متن کامل

لیزر در دندانپزشکی ترمیمی

Today laser has a lot of usage in medicine and dentistry. In the field of dentistry, laser is used in soft tissue surgery, sterilization of canals (in root canal therapy) and in restorative dentistry laser is used for cavity preparation, caries removal, sealing the grooves (in preventive dentistry), etching enamel and dentin, composite polymerization and removal of tooth sensitivity. The use of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Photomedicine and laser surgery

دوره 27 2  شماره 

صفحات  -

تاریخ انتشار 2009