Circadian variations in ischemic threshold and their relation to the occurrence of ischemic episodes.
نویسندگان
چکیده
BACKGROUND The occurrence of ischemic episodes during daily activity has been reported to exhibit a bimodal circadian distribution, yet its relation to the ischemic threshold (heart rate at 1-mm ST segment depression) has not been explored. METHODS AND RESULTS To determine whether the ischemic threshold during daily activity exhibits a circadian pattern that might relate to the frequency of occurrence of ischemic episodes, we studied the time of occurrence and the heart rate at onset of ischemia in 1,371 ischemic episodes recorded in 41 patients with stable coronary disease, positive exercise testing, and repeated ischemic episodes during ambulatory ECG monitoring (AEM). All patients had 7 days of AEM; 23 were off any anti-ischemic therapy, while 18 were on low dose of beta-blockers. The occurrence of ischemic episodes exhibited the typical bimodal circadian distribution with a prominent peak between 7:00 and 11:00 AM and a second less prominent peak between 6:00 and 9:00 PM. The threshold of myocardial ischemia exhibited a different single-peaked circadian distribution; it was lowest between 1:00 and 3:00 AM and highest between 10 AM and 1 PM. Time series analyses indicated a strong hour-by-hour trend of each of the two circadian distributions, whereas the two series cross-correlated maximally at a lag of zero hours (p < 0.01), indicating a complex interplay between myocardial oxygen demand and supply in determining the occurrence of ischemic episodes during daily activity. The morning increase in the frequency of ischemic episodes could not be attributed to a reduced threshold but rather to an increase in demand. The low threshold at night-time might probably indicate that the mechanism of ischemia during these hours is reduced coronary flow due to increased coronary tone. Secondary analyses for several predefined patients' subsets gave similar results. Patients who received low-dose beta-blockers maintained the bimodal circadian distribution of the occurrence of ischemic episodes, whereas the ischemic threshold exhibited a constant pattern with no circadian changes. CONCLUSIONS Our results demonstrate that myocardial oxygen demand is a major determinant of daily ischemia, yet changes in the ischemic threshold that probably reflect dynamic changes in coronary tone play also an important role. The relative contribution of increased demand and decreased threshold to the genesis of ischemic episodes during daily activity can be assessed by AEM and may help to optimize medical therapy.
منابع مشابه
Circadian variation in ischemic threshold. A mechanism underlying the circadian variation in ischemic events.
BACKGROUND There is a circadian pattern in the occurrence of cardiac events in patients with coronary artery disease. Whether changes in coronary vascular tone contribute to these phenomena is unknown. We measured the ischemic threshold, defined as either the heart rate or rate-pressure product at 1-mm ST segment depression during treadmill exercise and used it as an index of the lowest coronar...
متن کاملThe relation between body mass index and prevalence of ischemic heart disease in type 2 diabetic patients
Background: The transition from communicable to non-communicable diseases has occurred over many years in all countries of the world, even in developing countries. Diabetes and its ischemic heart complication are among the most important second groupe diseases. In recent years, discussions about the role of obesity and weight gain have risen again as a risk factor for both diseases. Our objecti...
متن کاملIschemic Threshold A Mechanism Underlying the Circadian Variation in Ischemic Events
Background. There is a circadian pattern in the occurrence of cardiac events in patients with coronary artery disease. Whether changes in coronary vascular tone contribute to these phenomena is unknown. We measured the ischemic threshold, defined as either the heart rate or rate-pressure product at 1-mm ST segment depression during treadmill exercise and used it as an index of the lowest corona...
متن کاملCircadian variation of malignant ventricular arrhythmias in patients with ischemic and nonischemic heart disease after cardioverter defibrillator implantation. European 7219 Jewel Investigators.
OBJECTIVES The purpose of this study was to examine the circadian variation of ventricular arrhythmias detected by an implantable cardioverter defibrillator in patients with and without ischemic heart disease. BACKGROUND Previous studies have shown a circadian variation of ventricular arrhythmias, sudden death and myocardial infarction with a peak occurrence in the morning hours. The circadia...
متن کاملA Mechanism Underlying the Circadian Variation in Ischemic Events
Background. There is a circadian pattern in the occurrence of cardiac events in patients with coronary artery disease. Whether changes in coronary vascular tone contribute to these phenomena is unknown. We measured the ischemic threshold, defined as either the heart rate or rate-pressure product at 1-mm ST segment depression during treadmill exercise and used it as an index of the lowest corona...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 87 3 شماره
صفحات -