Validation of experimental whole-body SAR assessment method in a complex indoor environment.

نویسندگان

  • Aliou Bamba
  • Wout Joseph
  • Gunter Vermeeren
  • Emmeric Tanghe
  • Davy Paul Gaillot
  • Jørgen B Andersen
  • Jesper Ødum Nielsen
  • Martine Lienard
  • Luc Martens
چکیده

Experimentally assessing the whole-body specific absorption rate (SAR(wb) ) in a complex indoor environment is very challenging. An experimental method based on room electromagnetics theory (accounting only the line-of-sight as specular path) is validated using numerical simulations with the finite-difference time-domain method. Furthermore, the method accounts for diffuse multipath components (DMC) in the total absorption rate by considering the reverberation time of the investigated room, which describes all the losses in a complex indoor environment. The advantage of the proposed method is that it allows discarding the computational burden because it does not use any discretizations. Results show good agreement between measurement and computation at 2.8 GHz, as long as the plane wave assumption is valid, that is, at large distances from the transmitter. Relative deviations of 0.71% and 4% have been obtained for far-field scenarios, and 77.5% for the near field-scenario. The contribution of the DMC in the total absorption rate is also quantified here, which has never been investigated before. It is found that the DMC may represent an important part of the total absorption rate; its contribution may reach up to 90% for certain scenarios in an indoor environment.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validation of Heat Pressure Assessment (HPA) Method and WBGT index in Iranian South Oil Company

Introduction: Determining methods for assessing heat stress in different work environments is one of the major challenges for researchers in this field. The purpose of this study was to validate WBGT index and heat pressure assessment (HPA) by some physiological responses in Iranian South Oil Company. Material and Methods: This descriptive-analytical study was carried out on 154 employees of K...

متن کامل

Whole-Body Averaged SAR Estimation for Postured Japanese Human Models using Cylindrical-External Field Scanning Measurement for UHF Plane-Wave Exposure -Numerical Analyses for Measurement Validation-

The purpose of this study is to establish a whole-body averaged specific absorption rate (WB-SAR) experimental estimation method using the total power absorbed by humans; a cylindrical-external field scanning technique is used to measure the radiated RF (radiofrequency) power. This technique is adopted with the goal of simplifying the exposure dosimetry of humans of different postures and/or si...

متن کامل

Statistical multi-path exposure method for assessing the whole-body SAR in a heterogeneous human body model in a realistic environment.

Assessing the whole-body absorption in a human in a realistic environment requires a statistical approach covering all possible exposure situations. This article describes the development of a statistical multi-path exposure method for heterogeneous realistic human body models. The method is applied for the 6-year-old Virtual Family boy (VFB) exposed to the GSM downlink at 950 MHz. It is shown ...

متن کامل

An Indoor Positioning System Based on Wi-Fi for Energy Management in Smart Buildings

To offer indoor services to occupants in the context of smart buildings, it is necessary to consider information concerning to the identity and location of the occupants. This paper proposes an indoor positioning system (IPS) based on Wi-Fi fingerprint and K-nearest neighbors (KNN) method. The positioning of a mobile device (MD) using Wi-Fi technology involves online and offline phases. In this...

متن کامل

Patient-specific SAR models and in vivo validation

Introduction For parallel transmission, traditional safety concepts need to be re-assessed, as the local specific absorption rate (SAR) becomes a limiting safety constraint [1] that depends on the pulse design as well as on the individual patient anatomy. Whereas the whole-body SAR can be monitored during the scan, the local SAR cannot be measured in clinical practice. Instead, numerical simula...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Bioelectromagnetics

دوره 34 2  شماره 

صفحات  -

تاریخ انتشار 2013