Permanent epicardial pacing in pediatric patients: seventeen years of experience and 1200 outpatient visits.

نویسندگان

  • M I Cohen
  • D M Bush
  • V L Vetter
  • R E Tanel
  • T S Wieand
  • J W Gaynor
  • L A Rhodes
چکیده

BACKGROUND The purpose of this study was to evaluate the long-term outcome of all pediatric epicardial pacing leads. METHODS AND RESULTS All epicardial leads and 1239 outpatient visits between January 1, 1983, and June 30, 2000, were retrospectively reviewed. Pacing and sensing thresholds were reviewed at implant, at 1 month, and at subsequent 6-month intervals. Lead failure was defined as the need for replacement or abandonment due to pacing or sensing problems, lead fracture, or phrenic/muscle stimulation. A total of 123 patients underwent 207 epicardial lead (60 atrial/147 ventricular, 40% steroid) implantations (median age at implant was 4.1 years [range 1 day to 21 years]). Congenital heart disease was present in 103 (84%) of the patients. Epicardial leads were followed for 29 months (range 1 to 207 months). The 1-, 2-, and 5-year lead survival was 96%, 90%, and 74%, respectively. Compared with conventional epicardial leads, both atrial and ventricular steroid leads had better stimulation thresholds 1 month after implantation; however, only ventricular steroid leads had improved chronic pacing thresholds (at 2 years: for steroid leads, 1.9 muJ [from 0.26 to 16 mu]; for nonsteroid leads, 4.7 muJ [from 0.6 to 25 muJ]; P<0.01). Ventricular sensing was significantly better in steroid leads 1 month after lead implantation (at 2 years: for steroid leads, 8 mV [from 4 to 31 mV]; for nonsteroid leads, 4 mV [from 0.7 to 10 mV]; P<0.01). Neither congenital heart disease, lead implantation with a concomitant cardiac operation, age or weight at implantation, nor the chamber paced was predictive of lead failure. CONCLUSIONS Steroid epicardial leads demonstrated relatively stable acute and chronic pacing and sensing thresholds. In this evaluation of >200 epicardial leads, lead survival was good, with steroid-eluting leads demonstrating results similar to those found with historical conventional endocardial leads.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pacing therapy in children.

BACKGROUND The importance of ventricular pacing site in pediatric pacemaker therapy has gradually become recognized. We reviewed our experience with a left ventricular (LV)-prioritized pacing strategy. METHODS AND RESULTS: Between 2000 and 2012, 60 patients underwent 76 permanent pacemaker implantations. Eight of the 29 reoperations involved ventricular lead repositioning for pacing-induced ven...

متن کامل

Performance of steroid eluting bipolar epicardial leads in pediatric and congenital heart disease patients: 15 years of single center experience

OBJECTIVE Cardiac pacing is sometimes required for patients with congenital heart disease for various reasons. Because of complex anatomy, repetitive previous heart surgery and patient size, epicardial leads are of special importance in these patients. Using epicardial leads has been discussed controversly regarding pacing performance and lead survival. The aim of this study was to review the l...

متن کامل

Permanent epicardial pacing in children: long-term results and factors modifying outcome.

AIMS To evaluate the results of permanent epicardial pacing in children. METHODS AND RESULTS All consecutive patients from one country (n = 119, period 1977-2009) undergoing permanent epicardial pacemaker implantation at <18 years of age (median 1.8 years, inter-quartile range 0.3-6.4 years) were studied retrospectively. Median patient follow up was 6.4 years (inter-quartile range 2.9-11.1 ye...

متن کامل

Novel Technique of Dual Chamber Pacing Through Mini-thoracotomy and Transatrial Endocardial Active Fixation Lead Insertion for Epicardial Pacing Lead Malfunction

Epicardial pacing lead fixation is employed in patients with cavopulmonary anastamosis (Glenn shunts) when they need permanent pacing. Epicardial pacing in these patients may malfunction due to high pacing thresholds or diaphragmatic pacing. A novel technique of transatrial insertion of two endocardial screw-in pacing leads through right anterolateral minithoracotomy could achieve synchronous a...

متن کامل

Safety and imaging quality of MRI in pediatric and adult congenital heart disease patients with pacemakers.

BACKGROUND Magnetic resonance imaging (MRI) is a standard of care in evaluating many disease processes. Given concerns about device damage or movement, programming changes, lead heating, inappropriate pacing, and image artifact, MRI is contraindicated in pacemaker patients. Despite this, studies have demonstrated safety and efficacy of MRI in adults with acquired heart disease and endocardial p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 103 21  شماره 

صفحات  -

تاریخ انتشار 2001