Magnetic Field of RF Coil Measurement by NMR Method

نویسندگان

  • P. Andris
  • A. Ericsson
چکیده

A spectroscopic imaging technique with high spatial resolution was used for the measurement of the static magnetic field homogeneity of RF coils. Measured magnetic fields of optimised and not optimised saddle-shaped coils were compared with the theoretical calculations. Results are in good qualitative agreement between calculated and measured magnetic field distributions. Quantitative disagreements however appeared in some experiments. We suppose that the method is suitable for magnetic field measurement of RF coils operating at frequencies where RF magnetic field may be replaced by the static magnetic field.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences

Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of  non-homogeneity in RF receive and transmit. This can be the most effective source of error in  quantitative  studies  in  MRI  imaging.  Part  of  this  non-homogeneity  demonstrates  the  characteristics of RF coil and part of it is due to the interaction of RF field with the material being  imaged...

متن کامل

Nmr Imaging of Solids with a Surface Coil Introduction

Nuclear magnetic resonance (NMR) imaging [1] usually exploits the dependence of the resonance frequency (generally in the rf band) on the magnetic field strength to map spatial position onto a frequency spectrum. The magnetic field strength is given a known spatial dependence and the spins are uniformly excited with an rf field. The uniform rf field is generally produced inside a cylindrical rf...

متن کامل

The Measurement of Low Frequency Magnetic Field of Two Kinds of GSM900 Mobile Phone

Introduction:  The  use  of  mobile  communication  systems  has  dramatically  increased  over  the  past  decade. Although many studies have been performed to determine the effect of radio frequency (RF) but  less attention has been paid to the possible biological impact of exposure to extremely low frequency  (ELF) components.   The objective of this study is two folds. One is to design the ...

متن کامل

3-D RF Coil Design Considerations for MRI

High-frequency coils are widely used in medical applications, such as Magnetic Resonance Imaging (MRI) systems. A typical medical MRI includes a local radio frequency transmit/receive coil. This coil is designed for maximum energy transfer or wave transfer through magnetic resonance. Mutual inductance is a dynamic parameter that determines the energy quantity to be transferred wirelessly by ele...

متن کامل

An improved shielded RF transmit coil for low-frequency NMR and MRI.

We describe an actively shielded cylindrical RF transmit coil producing a highly uniform internal field (±0.5%) over an extended volume and a strongly suppressed (÷20) external field. Direct field mapping and experimental checks using in-situ NMR and MRI of polarised (3)He at low temperature demonstrate performance consistent with numerical field computations.