Collateral configuration of the circle of Willis: transcranial color-coded duplex ultrasonography and comparison with postmortem anatomy.

نویسندگان

  • A W Hoksbergen
  • B Fülesdi
  • D A Legemate
  • L Csiba
چکیده

BACKGROUND AND PURPOSE The anterior communicating artery (AcoA) and posterior communicating arteries (PcoA) of the circle of Willis provide the main route for collateral blood flow in cases of carotid artery obstruction. Transcranial color-coded duplex ultrasonography (TCCD) allows real-time measurement of the collateral function of the AcoA and PcoA. The primary objective of this study was to determine the collateral artery threshold diameters for supplying collateral flow. METHODS In 12 acute stroke patients with a median age of 75 years (51 to 91 years), the collateral integrity of the circle of Willis as assessed by TCCD and carotid compression tests was compared with their postmortem anatomy. The lengths and diameters of the collateral arteries were measured. RESULTS TCCD demonstrated absent anterior collateral flow in 3 patients. In 1 of these patients, absence of anterior cross-flow was due to an occluded anterior cerebral artery, which was revealed at autopsy. Absent posterior collateral flow was found in 14 hemispheres. In 2 of these hemispheres, autopsy revealed a fetal configuration of the posterior cerebral artery hampering posterior collateral flow. The median (range) diameters as found at autopsy of the functional (n=19) and nonfunctional (n=16) collateral arteries of the circle of Willis were 1.1 (0.4 to 2.0) and 0.5 (0.3 to 0.7) mm, respectively (P=0.003). PcoA diameters were found to correlate negatively (rho=-0. 50, P=0.01) to the diameters of their accessory P1 segments. CONCLUSIONS The threshold diameter allowing for cross-flow through the primary collateral arteries of the circle of Willis is between 0. 4 and 0.6 mm.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Collateral variations in circle of willis in atherosclerotic population assessed by means of transcranial color-coded duplex ultrasonography.

BACKGROUND AND PURPOSE Transcranial color-coded duplex ultrasonography combined with common carotid artery (CCA) compression can be used to assess the collateral function of the circle of Willis. The aim of this study was to assess the unknown fraction of hemodynamic functional anterior and posterior communicating arteries (AcoA and PcoA, respectively) in an atherosclerotic population with no c...

متن کامل

Assessment of the collateral function of the circle of Willis: three-dimensional time-of-flight MR angiography compared with transcranial color-coded duplex sonography.

BACKGROUND AND PURPOSE Identification of the intracranial collaterals assists in identifying patients with severe occlusive disease of the internal carotid arteries who are at lower risk of transient ischemic attacks (TIAs) and stroke. We investigated the usefulness of MR angiography in identifying functional collaterals of the circle of Willis. METHODS MR angiography of the circle of Willis ...

متن کامل

Comparison of transcranial power Doppler and contrast-enhanced color-coded sonography in the identification of intracranial arteries.

Power-based transcranial color-coded sonography and contrast-enhanced transcranial color-coded sonography are ultrasonographic techniques that allow improved visualization of vascular structures. The present study was designed to investigate and compare the diagnostic capacity and applicability of both methods in the assessment of intracranial vessels of the circle of Willis (33 patients) and t...

متن کامل

Visualization of the basilar artery by transcranial color-coded duplex sonography : comparison with postmortem results.

BACKGROUND AND PURPOSE Transcranial color-coded sonography (TCCS) via the suboccipital approach allows direct and continuous visualization of the basilar artery (BA). In this study, we intended to evaluate the ability of native TCCS in visualizing the length of the BA by means of a comparison with postmortem measurements. METHODS The BA was prospectively studied by TCCS shortly before death (...

متن کامل

Transcranial color-coded duplex sonography in the evaluation of collateral flow through the circle of Willis.

PURPOSE To determine the sensitivity, specificity, and positive and negative predictive values of transcranial color-coded duplex sonographic (TCCD) evaluation of cross flow through the anterior (ACoA) and posterior (PCoA) communicating arteries in patients with occlusive cerebrovascular disease. METHODS We studied prospectively 132 patients (37 women, 95 men; mean age, 60 years) with stenose...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 31 6  شماره 

صفحات  -

تاریخ انتشار 2000