Determination of fluid leakages in the different screw-retained implant-abutment connections in a mechanical artificial mouth.

نویسندگان

  • D Martin-Gili
  • M Molmeneu
  • M Fernandez
  • M Punset
  • Ll Giner
  • J Armengou
  • F Javier Gil
چکیده

This study shows the potential risk of microfiltration between two different types of implant-abutment connections screwed at 45 Ncm: external and internal. For the first time the use of a mechanical artificial mouth is used with the values (compression and torsion loads with a frequency of 2 Hz) of the human chewing. The mechanical tests were performed with an artificial saliva at 37°C. The microgap in the connection was measured by an Image Analysis software incorporated in a high resolution scanning electron microscopy. Implant connections were filled with methylene blue by using self-adjustable precision pipettes and the quantity of leakage was determined by high sensitivity spectometry. We showed that the internal connection has lower microgaps compared to the external ones and these microgaps increased with the number of mechanical cycles. The leakage of methylene blue was higher when the external connection was performed. Microgaps and the influence of the mechanical loads are very important for the long-term behavior avoiding the bacteria colonization in the dental implants. These aspects should be known by the implantologists.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Abutment Connection Type and Cyclic Loading on Removal Torque Value

Background and Aim: Maintaining the primary torque of the abutment screw is a common problem related to implant-supported restorations; a failure in this respect often leads to screw loosening. The abutment screw plays a critical role in the long-term stability of restorations. This study aimed to assess the effect of two abutment connection types with and without cyclic loading on removal torq...

متن کامل

Comparison of the Effect of Two Different Abutment Diameters on Detorque Value Using Cyclic Loading and Thermocycling

Background and Aim: Screw loosening is a common problem with both screw-retained and cemented implant restorations. It is assumed that the abutment diameter affects detorque value and screw loosening. We aimed to determine the effect of two different abutment diameters on detorque value using cyclic loading and thermocycling. Materials and Methods: This in-vitro experimental study was conducte...

متن کامل

Fluids and microbial penetration in the internal part of cement-retained versus screw-retained implant-abutment connections.

BACKGROUND It has been recently observed that in implants with screw-retained abutments, in in vitro as well as in vivo conditions, bacteria can penetrate inside the internal cavity of the implant as a consequence of leakage at the implant-abutment interface. An alternative to screw-retained abutments is represented by implants that can receive cemented abutments. In this case, the abutment goe...

متن کامل

Management of a malpositioned implant using custom abutment and screw-retained fixed dental prosthesis.

A 32-year-old woman with missing permanent mandibular right molars and left first molar presented for treatment. One of the implants were misaligned during the placement due to sudden mouth closure of the patient. All implants success fully osseointegrated. However, the misaligned implant resulted in substantial mechanical and esthetic restorative challenges. The prosthodontic treatment include...

متن کامل

Effect of implant connection and restoration design (screwed vs. cemented) in reliability and failure modes of anterior crowns.

The mechanical performance of cemented or screw-retained implant-supported crowns with an internal or external configuration is yet to be understood. This in vitro study evaluated the effect of screw-retained and cement-retained prostheses on internal and external implant-abutment connections. Thereby, the reliability and failure modes of crowns were investigated. Eighty-four implants (Emfils; ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of materials science. Materials in medicine

دوره 26 7  شماره 

صفحات  -

تاریخ انتشار 2015