The effect of various thread designs on the initial stability of taper implants

نویسندگان

  • Ju-Hee Park
  • Young-Jun Lim
  • Myung-Joo Kim
  • Ho-Beom Kwon
چکیده

STATEMENT OF PROBLEM Primary stability at the time of implant placement is related to the level of primary bone contact. The level of bone contact with implant is affected by thread design, surgical procedure and bone quality, etc. PURPOSE The aim of this study was to compare the initial stability of the various taper implants according to the thread designs, half of which were engaged to inferior cortical wall of type IV bone (Group 1) and the rest of which were not engaged to inferior cortical wall (Group 2) by measuring the implant stability quotient (ISQ) and the removal torque value (RTV). MATERIAL AND METHODS In this study, 6 different implant fixtures with 10 mm length were installed. In order to simulate the sinus inferior wall of type IV bone, one side cortical bone of swine rib was removed. 6 different implants were installed in the same bone block following manufacturer's recommended procedures. Total 10 bone blocks were made for each group. The height of Group 1 bone block was 10 mm for engagement and that of group 2 was 13 mm. The initial stability was measured with ISQ value using Osstell mentor® and with removal torque using MGT50 torque gauge. RESULTS In this study, we found the following results. 1. In Group 1 with fixtures engaged to the inferior cortical wall, there was no significant difference in RTV and ISQ value among the 6 types of implants. 2. In Group 2 with fixtures not engaged to the inferior cortical wall, there was significant difference in RTV and ISQ value among the 6 types of implants (P < .05). 3. There was significant difference in RTV and ISQ value according to whether fixtures were engaged to the inferior cortical wall or not (P < .05). 4. Under-drilling made RTV and ISQ value increase significantly in the NT implants which had lower RTV and ISQ value in Group 2 (P < .05). CONCLUSIONS Without being engaged to the inferior cortical wall fixtures had initial stability affected by implant types. Also in poor quality bone, under-drilling improved initial stability.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the Effect of Ball and Bar Attachment Designs on Retention and Stability of Mandibular Implant-Supported Overdentures

Objectives: The present study evaluated the effect of bar and ball attachment designs on retention and stability of a mandibular overdenture supported by four implants. Methods: An edentulous mandibular acrylic resin model with four implants in the anterior part of the ridge (A, B, D and E) was fabricated. A metal framework simulating the overdenture was also fabricated. Totally, 30...

متن کامل

Effect of implant design on primary stability using torque-time curves in artificial bone

BACKGROUND Primary stability following implant placement is essential for osseointegration and is affected by both implant design and bone density. The aim of this study was to compare the relationships between torque-time curves and implant designs in a poor bone quality model. METHODS Nine implant designs, with five implants in each category, were compared. A total of 90 implants (Straumann...

متن کامل

Evaluating the impact of length and thread pitch on the stress distribution in dental implants and surrounding bone using finite element method

 longevity of osseointegrated implants are intensely influenced by biomechanical factors. Control of these factors prevents mechanical complications, which include fracture of screws, components, or materials veneering the framework. In this study, the impact of length and threads pitch of dental implants on the stress distribution and maximum Von Mises stress in implant-abutment complex and ja...

متن کامل

Thread Pitch Variant in Orthodontic Mini-screws: A 3-D Finite Element Analysis

Orthodontic miniscrews are widely used as temporary anchorage devices to facilitate orthodontic movements. Miniscrew loosening is a common problem, which usually occurs during the first two weeks of treatment. Macrodesign can affect the stability of a miniscrew by changing its diameter, length, thread pitch, thread shape, tapering angle and so on. In this study, a 3-D finite element analysis wa...

متن کامل

Immediate loading in dental implants ( A literature review )

Immediate loading in dental implants ( A literature review ) Dr. Seyedan K.,1 Dr. Hafezeqoran A.,2 Dr. Sazgara H.3 1Assistant Professor, Department of Prosthodentists,Dental School Shahid Beheshti University of Medical Sciences,Tehran, Iran.2Dentist, Post Graduate Student, Department of Prosthodontics, Dental School, Shahid Beheshti University of Medical Sciences, Tehran-Iran.3Associate Profess...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2009