A microfluidic protease activity assay based on the detection of fluorescence polarization.
نویسندگان
چکیده
This article describes a fluorescence polarization (FP)-based protease assay on a microfluidic device that is compatible with fast and reproducible analyses of protease activities. The optical systems were arranged for simultaneously measuring fluorescence intensities of vertical and horizontal polarization planes, and the binding of tetramethylrhodamine (TMR) labeled-biotin with streptavidin was utilized for optimizing FP detection in continuously flowing solutions within 74-microm wide, 12-microm deep microchannels of a glass chip. In developing off-chip FP-based assays for proteinase K, trypsin, papain and elastase, TMR conjugated-casein protein (TMR-alpha-casein) was employed as a universal substrate. After optimization of the hydrodynamic flow control to allow complete mixing of TMR-alpha-casein and short proteolysis time as possible, and of buffer composition to minimize protein sticking problems, the developed assay was transferred to the microfluidic chip by monitoring FP changes of TMR-alpha-casein in the main microchannel. The results indicate that the proposed device would serve as an integrated microfluidic platform with automated injection of reacting species, diffusion-controlled mixing, reaction and detection for protease activities without the need to separate the products.
منابع مشابه
Detection of Neuraminidase Activity in Pseudomonas aeruginosa PAO1
Objective(s) Some properties of neuraminidase produced by Pseudomonas aeruginosa PAO1 growth in a defined medium (BHI) were examined and evaluated for its features. Materials and Methods The obtained supernatant enzyme of P. aeruginosa PAO1 cultures was used in a sensitive fluorometric assay by using 2'-(4-methylumbelliferyl) a-D-N acetylneuraminic acid as substrate. As hydrolyzing MUN with ...
متن کاملFluorescent Contrast agent Based on Graphene Quantum Dots Decorated Mesoporous Silica Nanoparticles for Detecting and Sorting Cancer Cells
Background and Objectives: The inability of classic fluorescence-activated cell sorting to single cancer cell sorting is one of the most significant drawbacks of this method. The sorting of cancer cells in microdroplets significantly influences our ability to analyze cancer cell proteins. Material and Methods: We adapted a developed microfluidic device as a 3D in vitro model to sorted MCF-7 c...
متن کاملUltrasensitive endonuclease activity and inhibition detection using gold nanoparticle-enhanced fluorescence polarization.
We have developed a highly sensitive and selective fluorescence polarization assay method based on the specificity of the DNA cleavage reaction with the enhancement of gold nanoparticles (AuNPs) for assaying endonuclease activity and inhibition. This assay can detect EcoRI endonuclease down to 5.0×10(-4) U mL(-1) with a detection range from 5.0×10(-4) to 10 U mL(-1).
متن کاملComparison of Static and Microfluidic Protease Assays Using Modified Bioluminescence Resonance Energy Transfer Chemistry
BACKGROUND Fluorescence and bioluminescence resonance energy transfer (F/BRET) are two forms of Förster resonance energy transfer, which can be used for optical transduction of biosensors. BRET has several advantages over fluorescence-based technologies because it does not require an external light source. There would be benefits in combining BRET transduction with microfluidics but the low lum...
متن کاملA New Class of Rhomboid Protease Inhibitors Discovered by Activity-Based Fluorescence Polarization
Rhomboids are intramembrane serine proteases that play diverse biological roles, including some that are of potential therapeutical relevance. Up to date, rhomboid inhibitor assays are based on protein substrate cleavage. Although rhomboids have an overlapping substrate specificity, substrates cannot be used universally. To overcome the need for substrates, we developed a screening assay using ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytica chimica acta
دوره 577 2 شماره
صفحات -
تاریخ انتشار 2006