Combined doppler and phased-array echocardiographic estimation of cardiac output.
نویسندگان
چکیده
The capability of a pulsed Doppler flowmeter combined with a phased-array imaging system to measure volume flow was tested in vitro and in patients undergoing cardiac catheterization. The Doppler-phased-array system (DPA) was used to determine vessel diameter and a superimposed cursor was used to locate the range and angle of the Doppler sample volume. DPA estimates of continuous flow through tubing in a water tank correlated strongly (r = 0.99) with measured flow corresponding to physiologic ranges from 3-12 l/min. For pulsatile flow in a water tank, a correlation of r = 0.86 with measured flow was obtained, whereas DPA estimates of cardiac outputs compared with Fick estimates in the 11 patients produced a correlation of r = 0.83. These data indicate that estimates of cardiac output are possible using the DPA approach.
منابع مشابه
Noninvasive Prediction of Transvalvular Pressure Gradient in Patients with Pulmonary Stenosis by Quantitative Iwo-dimensional Echocardiographic Doppler Studies
Recent studies suggest that maximal Doppler velocities measured within the jets that form downstream from stenotic valves can be used to predict aortic valve gradients. To test whether the Doppler method would be useful for evaluation and management of pediatric patients with right ventricular outflow obstruction, we evaluated pulmonary artery flow before catheterization in 16 children with pul...
متن کاملNoninvasive Prediction of Transvalvular Pressure Gradient in Patients with Pulmonary Stenosis by Quantitative Iwo-dimensional Echocardiographic Doppler Studies
Recent studies suggest that maximal Doppler velocities measured within the jets that form downstream from stenotic valves can be used to predict aortic valve gradients. To test whether the Doppler method would be useful for evaluation and management of pediatric patients with right ventricular outflow obstruction, we evaluated pulmonary artery flow before catheterization in 16 children with pul...
متن کاملNormal pulsed wave Doppler echocardiographic parameters of Turkmen horses of Iran
Turkmen horse is one of the oldest and purest breeds in the world, but there is no information on Doppler echocardiographic parameters in this horse. In the present study, pulsed-wave (PW) Doppler echocardiography was performed on 42 clinically normal 3- to 15-year-old racing Turkmen horses. No cardiac disease was detected with two-dimensional (2-D) real-time, M-mode, and colour flow mapping. D...
متن کاملPerformance of Target Detection in Phased-MIMO Radars
In this paper, the problem of target detection in phased-MIMO radars is considered and target detection performance of phased-MIMO radars is compared with MIMO and phased-array radars. Phased-MIMO radars combine advantages of the MIMO and phased-array radars. In these radars, the transmit array will be partitioned into a number of subarrays that are allowed to overlap and each subarray transmit...
متن کاملHIGHLIGHTED TOPIC Physiology of Aging Echocardiographic assessment of age-associated changes in systolic and diastolic function of the female F344 rat heart
Boluyt, Marvin O., Kimber Converso, Hyun Seok Hwang, Agdas Mikkor, and Mark W. Russell. Echocardiographic assessment of age-associated changes in systolic and diastolic function of the female F344 rat heart. J Appl Physiol 96: 822–828, 2004. First published October 10, 2003; 10.1152/japplphysiol.01026.2003.—Aging is associated with hypertrophy, dilatation, and fibrosis of the left ventricle (LV...