Meeting the Requirements of EN12916:2006 (IP391/07) Using Agilent 1200 Series HPLC Systems

نویسنده

  • Michael Woodman
چکیده

The performance of diesel fuel is predominantly determined by its ignition quality. This parameter is known as the Cetane number. The Cetane number describes the volume % Cetane (hexadecane) present in a mixture of Cetane and 1-Methylnaphthalene. Generally, in order to provide the best performance and lifetime of an engine, the amount of aromatics in diesel should be as low as possible. For the analysis of nonaromatics and aromatics in diesel fuel and petroleum distillates boiling in the range 150 °C to 400 °C, there exists an IP Method (391/07), which uses HPLC with refractive index detection. The two compound classes (aromatics and non-aromatics) are separated using normal phase HPLC and a column which has little affinity for non-aromatic but pronounced selectivity for aromatic hydrocarbons [1]. Recent growth in biodiesel production created a demand for analysis of petrodiesel and petrodiesel/ biodiesel blends. In this method revision, fatty acid methyl esters (FAME) originating from biodiesel sources must elute after a tetra-aromatic marker peak, chrysene, which facilitates improved accuracy of large PAH molecules without interference from FAME. The refractive index detector is used because this detector responds to both non-aromatic and aromatic hydrocarbons. Authors Michael Woodman Agilent Technologies, Inc. Chemical Analysis Solutions 2850 Centerville Road Wilmington, DE 19808 USA Malgorzata Sierocinska Agilent Technologies European Field Support Centre Waldbronn Germany Application Note

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of Radix Bupleuri (Chaihu) using Agilent 1200 Series LC Systems with Evaporative Light Scattering Detector

This Application Note describes the development of conventional HPLC and Rapid Resolution LC (RRLC) methods for the analysis of Buplerui (Chaihu). A comparison of fingerprint chromatograms of different Buplerui samples showed different peak profiles of different TCMs collected from different places. The method for the Agilent 1200 Series Evaporative Light Scattering Detector (ELSD) was optimize...

متن کامل

Comparison of system suitability results according to USP method USP/NF 23 for the analysis of Paracetamol (Acetaminophen) and Aspirin in pain relievers

This analysis used the system suitability test, developed on an Agilent 1200 Series LC system to test whether the Agilent 1220 and Agilent 1260 Infinity LC systems fulfilled the acceptance criteria. The chromatographic conditions of the system suitability test transferred to the Agilent 1260 and Agilent 1220 Infinity LC systems without changes. The results obtained were compared for compliance ...

متن کامل

Determination of Melamine Residue in Milk Powder and Egg Using Agilent SampliQ Polymer SCX Solid Phase Extraction and the Agilent 1200 Series HPLC/UV

This method was developed for the determination of melamine in milk powder and egg. Solid phase extraction (SPE) and HPLC/UV are used consistent with the Chinese regulatory method. The sample preparation is performed using a polymeric mixed mode strong cation exchange resin. The separation and detection are performed by HPLC/UV. The limit of detection is 10 μg/kg. Linear calibration curves were...

متن کامل

Fast screening of mobile and stationary phases with the Agilent 1290 Infinity LC and seamless method transfer to an Agilent 1200 Series LC using ISET

This Application Note describes how the Agilent 1290 Infinity LC System Method Development Solution was used to find optimum separation conditions for degradation products of a pharmaceutical preparation. Having evaluated the optimum combination, a transfer to conventional conditions was performed. Finally, the Agilent Intelligent System Emulation Technology (ISET) of the 1290 Infinity LC was u...

متن کامل

Using nanospray HPLC-Chip/TOF for routine high sensitivity metabolite identification

Nanospray LC-MS analysis of dextromethorphan (DEM) and its metabolites was performed with the Agilent 1200 Series HPLC-Chip/TOF system. Automated nanospray HPLC-Chips with the high sensitivity TOF allowed detection of all DEM metabolites, following incubation at concentration levels 100-fold lower than normally used. In addition, system response was linear over a wide concentration range for me...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011