Images in anesthesiology: radial artery spasm in an infant as documented by high-frequency micro-ultrasound.
نویسندگان
چکیده
1254 May 2014 H micro-ultrasound is a new, preclinical technology that utilizes higher frequencies compared to conventional ultrasound. During a feasibility trial using high-frequency micro-ultrasound for vascular access in children, radial artery spasm in an 8-month-old male child was uniquely documented with a 50-MHz probe. The intraluminal diameter before attempted cannulation was 2.1 mm (fig. A) and was 0.4 mm afterward (fig. B), which explains why the 0.38-mm diameter guide-wire could not be advanced into the vessel in spasm. The radial artery contains a high density of α-1 adrenoceptors and is more susceptible to spasm compared to many other arteries.1 The occurrence of spasm after successful cannulation can be directly treated with intraarterial administration of a vasodilator, such as nitroglycerine or verapamil.2 However, when arterial spasm occurs before successful cannulation of the artery, subsequent cannulation may be impossible, as our picture shows. When this occurs, three choices remain: choose a new site for cannulation, wait for the spasm to resolve if access is required in that artery, or treat the arteriospasm. Treatment of arteriospasm to facilitate cannulation of the segment in spasm is not well studied.3 reported treatment options include systemic administration of a vasodilator, with the risk of systemic hypotension, and subcutaneous periarterial administration of nitroglycerin, with or without local anesthetic.3 Subcutaneous nitroglycerine can be effective in rapidly reestablishing a palpable radial pulse,3 and ultrasound may aid in evaluating the extent of vessel in spasm and relaxation of spasm after treatment.
منابع مشابه
Non-invasive estimation of cardiac wall stress by using tissue doppler-echocardiography ultrasound images: People with coronary artery stenosis
In this study, a method for non-invasive estimation of stress on the heart wall in the diastole phase is presented using ultrasound echocardiography and tissue Doppler imaging. The aim of this study was to evaluate the stress on the heart wall as a pre-diagnosis to identify people with coronary artery stenosis. 29 patients with stenosis of more than 70%, 30 patients with stenosis of 50 to 7...
متن کاملBedside Ultrasonography for Early Diagnosis of Occult Radial Head Fractures in Emergency Room: A CTComparative Diagnostic Study
Background: Some of the Mason type I fractures cannot be detected on early radiographic images. These occultfractures are considered as a diagnostic challenge for physicians. Our aim was to determine the value of bedsideultrasonography for the detection of Mason I radial head fractures that are non-visible in early X-ray’s.Methods: A prospective blind single-center diagnostic study was conducte...
متن کاملGenerating and Focusing the Ultrasound Waves Using Elastomer-based Capacitive Micro-Speakers
Ultrasound wave is a kind of waves with the frequency higher than the human audible frequency. Although ultrasound was first used for military identification purposes, it has been used for decades for various other applications, especially medical applications. Medical applications of ultrasound include diagnostic and therapeutic applications, such as for the treatment of cancer. In this paper,...
متن کاملThe effect of reactive artery hyperaemia on the radial strain of the brachial artery: Definition of optimum cuff position
Instruction: Measurement of brachial artery diameter variation by ultrasound methods has commonly been used to test the endothelial function. It is known that the artery diameter is increased by flow stimulation. Therefore in the present study, the effect of external obstruction, as flow stimulation, on the radial strain of the brachial artery was assessed. Also the biomechanical behavior of...
متن کاملAutomatic measurement of instantaneous changes in the walls of carotid artery with sequential ultrasound images
Introduction: This study presents a computerized analyzing method for detection of instantaneous changes of far and near walls of the common carotid artery in sequential ultrasound images by applying the maximum gradient algorithm. Maximum gradient was modified and some characteristics were added from the dynamic programming algorithm for our applications. Methods: The algorithm was evaluat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Anesthesiology
دوره 120 5 شماره
صفحات -
تاریخ انتشار 2014