Vacuum-assisted breast biopsy: A comparison of 11-gauge and 8-gauge needles in benign breast disease
نویسندگان
چکیده
BACKGROUND Minimal invasive breast biopsy is standard care for the diagnosis of suspicious breast lesions. There are different vacuum biopsy (VB) systems in use. The aim of the study was to determine the differences between the 8-gauge and the 11-gauge needle with respect to a) diagnostic reliability, b) complication rate and c) subjective perception of pain when used for vacuum-assisted breast biopsy. METHODS Between 01/2000 and 09/2004, 923 patients at St. Josefs-Hospital Wiesbaden underwent VB using the Mammotome (Ethicon Endosurgery, Hamburg). Depending on preoperative detection, the procedure was performed under sonographic or mammographic guidance under local anaesthesia. All patients included in the study were followed up both clinically and using imaging techniques one week after the VB and a second time after a median of 41 months. Excisional biopsy on the ipsilateral breast was an exclusion criteria. Subjective pain scores were recorded on a scale of 0 - 10 (0 = no pain, 10 = unbearable pain). The mean age of the patients was 53 years (30 - 88). RESULTS 123 patients were included in the study in total. 48 patients were biopsied with the 8-gauge needle and 75 with the 11-gauge needle. The use of the 8-gauge needle did not show any significant differences to the 11-gauge needle with regard to diagnostic reliability, complication rate and subjective perception of pain. CONCLUSION Our data show that there are no relevant differences between the 8-gauge and 11-gauge needle when used for VB. Under sonographic guidance, the use of the 8-gauge needle is recommended for firm breast tissue due to its sharp scalpel point and especially for complete removal of benign lesions. We did not find any advantages in the use of the larger 8-gauge needle compared to the 11-gauge needle in the mammography setting. The utilisation costs of the 8-gauge needle are somewhat higher.
منابع مشابه
Ultrasound-guided diagnostic breast biopsy methodology: retrospective comparison of the 8-gauge vacuum-assisted biopsy approach versus the spring-loaded 14-gauge core biopsy approach
BACKGROUND Ultrasound-guided diagnostic breast biopsy technology represents the current standard of care for the evaluation of indeterminate and suspicious lesions seen on diagnostic breast ultrasound. Yet, there remains much debate as to which particular method of ultrasound-guided diagnostic breast biopsy provides the most accurate and optimal diagnostic information. The aim of the current st...
متن کاملSonographically Guided Core Biopsy of the Breast: Comparison of 14-Gauge Automated Gun and 11-Gauge Directional Vacuum-Assisted Biopsy Methods
OBJECTIVE To compare the outcomes of 14-gauge automated biopsy and 11-gauge vacuum-assisted biopsy for the sonographically guided core biopsies of breast lesions. MATERIALS AND METHODS We retrospectively reviewed all sonographically guided core biopsies performed from January 2002 to February 2004. The sonographically guided core biopsies were performed with using a 14-gauge automated gun on ...
متن کاملBenign papillomas diagnosed on large-gauge vacuum-assisted core needle biopsy which span <1.5 cm do not need surgical excision.
The objective of our study is to determine if a carefully selected subset of benign breast papillomas (size ≤1.5 cm) can be safely followed by imaging surveillance instead of immediate surgical excision. Over a 6½-year period, 86 breast lesions were diagnosed as a benign papilloma (BP) utilizing an 11- or 8-gauge vacuum-assisted core needle biopsy (VACNB) device. In general, it was our intent t...
متن کاملBreast microcalcifications: retrieval failure at prone stereotactic core and vacuum breast biopsy--frequency, causes, and outcome.
PURPOSE To retrospectively determine the frequency and causes of failure to retrieve microcalcifications in nonpalpable lesions, as judged on a radiograph of the specimen, and to determine outcome in patients with those lesions. MATERIALS AND METHODS Informed consent was obtained from each patient prior to biopsy. The institutional review board approved this HIPAA-compliant study and granted ...
متن کاملStereotactic vacuum-assisted breast biopsy: our experience and comparison with stereotactic automated needle biopsy.
OBJECTIVES To evaluate and compare the outcome of stereotactically guided percutaneous, directional, vacuum-assisted breast biopsy (VAB) with the outcome of those performed with 14-gauge automated gun. METHODS Between January 2008 and January 2011, altogether 257 stereotactic biopsies were performed in our institute; 193 with the 14-gauge automated needle and 64 with a directional, vacuum-ass...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- World Journal of Surgical Oncology
دوره 6 شماره
صفحات -
تاریخ انتشار 2008