Clinical performance evaluation of a novel, automated chemiluminescent immunoassay, QUANTA Flash CTD Screen Plus.
نویسندگان
چکیده
The QUANTA Flash(®) CTD Screen Plus is a chemiluminescent immunoassay (CIA) for the detection of the major antinuclear antibodies (ANA) on the BIO-FLASH(®) platform. NOVA View(®) is an automated fluorescence microscope that acquires digital images of indirect immunofluorescent assay (IFA) slides. Our goal was to evaluate the clinical performance of the two automated systems and compare their performance to that of traditional IFA. Sera from patients with systemic autoimmune rheumatic diseases (SARD, n = 178), along with disease and healthy controls (n = 204), were tested with the CTD CIA and with NOVA Lite(®) HEp-2 ANA, using both the manual method of reading the IFA slides and the NOVA View instrument. The CTD CIA showed 78.1% sensitivity for SARD, coupled with 94.1% specificity. Manual IFA and NOVA View showed somewhat higher sensitivity (81.5 and 84.8% in SARD, respectively), but significantly lower specificity (79.4 and 64.7%, respectively). Both automated systems displayed somewhat different performance, due to the different principals of ANA detection: IFA with NOVA View digital image interpretation had higher sensitivity, while the CTD CIA showed higher specificity. With the added benefits of full automation, the new CTD CIA is an attractive alternative to traditional ANA screening.
منابع مشابه
Clinical Comparison of QUANTA Flash dsDNA Chemiluminescent Immunoassay with Four Current Assays for the Detection of Anti-dsDNA Autoantibodies
INTRODUCTION The objective of the present study was to compare QUANTA Flash dsDNA, a chemiluminescent immunoassay (CIA) on the BIO-FLASH, a rapid-response chemiluminescent analyzer, to three other anti-dsDNA antibody assays and to Crithidia luciliae indirect immunofluorescence test (CLIFT). METHODS In the first part of the study, 161 samples, 61 from patients suffering from systemic lupus ery...
متن کاملAnalytical and Clinical Comparison of Two Fully Automated Immunoassay Systems for the Diagnosis of Celiac Disease
OBJECTIVE Here we compared analytical and clinical performance characteristics of two novel automated assay systems for the detection of celiac disease (CD) specific antibodies: QUANTA Flash (INOVA Diagnostics, Inc.) and EliA (Thermo Scientific). METHODS A total of 74 biopsy-proven CD patients (2 with IgA deficiency) and 138 controls were tested by both methods. RESULTS Sensitivities of QUA...
متن کاملHighlights on Novel Technologies for the Detection of Antibodies to Ro60, Ro52, and SS-B
OBJECTIVE We aimed to compare a chemiluminescent immunoassay (CIA, QUANTA Flash) on BIO-FLASH with a multiplex flow immunoassay (MFI) on BioPlex 2200 for the detection of antibodies to Ro60, Ro52, and SS-B. METHODS The study included 241 samples, from patients suffering from systemic autoimmune diseases (n = 108) as well as disease controls (n = 133). All samples were tested for anti-Ro52, an...
متن کاملA Clinical Approach for Defining the Threshold between Low and Medium Anti-Cardiolipin Antibody Levels for QUANTA Flash Assays
The threshold between low and medium antibody levels for anticardiolipin (aCL) and anti-β2 glycoprotein I antibodies (aβ2GPI) for the diagnosis of antiphospholipid syndrome (APS) remains a matter of discussion. Our goal was to create a protocol for determining the low/medium antibody cut-off for aCL antibody methods based on a clinical approach, and utilize it to establish the clinically-releva...
متن کاملClinical performance evaluation of four automated chemiluminescence immunoassays for hepatitis C virus antibody detection.
Various automated chemiluminescence immunoassay (CLIA) analyzers for the detection of antibodies to hepatitis C virus (HCV) are now commercially available in clinical laboratories and are replacing conventional enzyme immunoassays. We investigated the performance of four anti-HCV CLIAs (the Architect Anti-HCV assay on the Architect i2000 system, the Vitros Anti-HCV assay on the Vitros ECiQ Immu...