Free water transport in children on peritoneal dialysis is higher with more biocompatible dialysis solutions, higher with older age and declines with time.
نویسندگان
چکیده
BACKGROUND Water transport in peritoneal dialysis occurs through small pores and aquaporins. Free water transport (FWT) occurs through aquaporins only and gives a reflection of peritoneal aquaporin function. In this study, FWT in children was calculated for the first time in different settings. METHODS A prospective cohort study was performed; 87 peritoneal equilibrium tests (PETs) were analysed in 65 patients. Three subgroups were analysed: patients with their first PET; patients in their second year on dialysis; patients in their third year on dialysis or thereafter. Patients using 3.86% glucose solution with low pH/high glucose degradation products (GDP) were compared to patients using 3.86% glucose solution with neutral pH/low GDP. Sixteen patients using neutral pH/low GDP solution were followed longitudinally. FWT was calculated using the dialysate/plasma ratio of sodium. RESULTS The proportional contribution of FWT was significantly higher in patients using dialysis solution with neutral pH/low GDP solution compared to patients using solutions with low pH/high GDP (50 versus 40%). Transcapillary ultrafiltration (TCUF) showed the same trend but was not statistically significant. Total FWT was higher as well. Higher FWT was observed with older age. In the longitudinal group, TCUF and water transport through small pores declined, while FWT remained stable in the first 1.5 years. The contribution of FWT increased in this period (48-61%), then slowly declined again to baseline level during the third year. CONCLUSIONS Total FWT and relative contribution of FWT were significantly higher with neutral pH/low GDP solution. This can reflect a better preservation of aquaporins. The decline in the contribution of FWT in long-term dialysis could hypothetically implicate aquaporin dysfunction or different trafficking of aquaporins.
منابع مشابه
Relation between Malnutrition–Inflammation–Atherosclerosis (MIA complex) in Diabetic Patients with Peritoneal Dialysis
Objective: Atherosclerosis disease, inflammation and malnutrition have strong association with end stage renal disease (ESRD). Diabetes mellitus (DM) is the most commonly ESRD causes. Diabetic nephropathy (DN) could be associated with inflammation. Type 2 diabetic patients with advanced nephropathy show the highest levels of inflammatory markers. This study was designed to determine the associa...
متن کاملComparison of Marital Satisfaction in Hemodialysis and Peritoneal Dialysis Patients
Alternative kidney treatments, including renal transplantation, hemodialysis (HD), and peritoneal dialysis (PD), are administered when severe kidney failure occurs and the kidney can no longer function. The present study compares different dimensions of marital satisfaction in HD and PD patients so as to assist physicians and patients in choosing their appropriate treatment. This cross-se...
متن کاملPeritoneal equilibration test with conventional 'low pH/high glucose degradation product' or with biocompatible 'normal pH/low glucose degradation product' dialysates: does it matter?
BACKGROUND The evaluation of the peritoneal transport characteristics is mandatory in peritoneal dialysis (PD) patients. This is usually performed in routine clinical practice with a peritoneal equilibration test (PET) using conventional dialysates, with low pH and high glucose degradation product (GDP) concentrations. An increasing proportion of patients are now treated with biocompatible dial...
متن کاملPeritoneal dialysis: from bench to bedside
Peritoneal dialysis was first employed in patients with acute renal failure in the 1940s and since the 1960s for those with end-stage renal disease. Its popularity increased enormously after the introduction of continuous ambulatory peritoneal dialysis in the end of 1970s. This stimulated both clinical and basic research. In an ideal situation, this should lead to cross-fertilization between th...
متن کاملCytotoxic Glucose Degradation Products in Fluids for Peritoneal Dialysis
During the standard heat sterilization process of the lactate–buffered peritoneal dialysis solutions, glucose (an osmotic active substance) degrades to form compounds called glucose degradation products which are cytotoxic and affect the survival of the peritoneal membrane. This case presentation is based on an observation of 224 aseptic peritonitis cases of unknown etiology. For the purpose of...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association
دوره 27 3 شماره
صفحات -
تاریخ انتشار 2012