Effect of heat and moisture exchangers on the prevention of ventilator-associated pneumonia in critically ill patients
نویسندگان
چکیده
Ventilator-associated pneumonia (VAP) remains one of the major causes of infection in the intensive care unit (ICU) and is associated with the length of hospital stay, duration of mechanical ventilation, and use of broad-spectrum antibiotics. We compared the frequency of VAP 10 months prior to (pre-intervention group) and 13 months after (post-intervention group) initiation of the use of a heat and moisture exchanger (HME) filter. This is a study with prospective before-and-after design performed in the ICU in a tertiary university hospital. Three hundred and fourteen patients were admitted to the ICU under mechanical ventilation, 168 of whom were included in group HH (heated humidifier) and 146 in group HME. The frequency of VAP per 1000 ventilator-days was similar for both the HH and HME groups (18.7 vs 17.4, respectively; P = 0.97). Duration of mechanical ventilation (11 vs 12 days, respectively; P = 0.48) and length of ICU stay (11 vs 12 days, respectively; P = 0.39) did not differ between the HH and HME groups. The chance of developing VAP was higher in patients with a longer ICU stay and longer duration of mechanical ventilation. This finding was similar when adjusted for the use of HME. The use of HME in intensive care did not reduce the incidence of VAP, the duration of mechanical ventilation, or the length of stay in the ICU in the study population.
منابع مشابه
Effectiveness of heat and moisture exchangers in preventing ventilator-associated pneumonia in critically ill patients: a meta-analysis
BACKGROUND Patients may acquire ventilator-associated pneumonia (VAP) by aspirating the condensate that originates in the ventilator circuit upon use of a conventional humidifier. The bacteria that colonize the patients themselves can proliferate in the condensate and then return to the airways and lungs when the patient aspirates this contaminated material. Therefore, the use of HME might cont...
متن کاملمقایسهی تاثیر کلرهگزیدین و مسواک زدن در پیشگیری از پنومونی ناشی از ونتیلاتور
Background and Objective: Ventilator-associated pneumonia is a common infection in intensive care units leading to increased morbidity and mortality. This study was conducted to examine the effects of mechanical (tooth brushing), pharmacological (topical oral chlorhexidine), and their combination (tooth brushing plus chlorhexidine) in oral care on preventing the ventilator-associated pneumonia ...
متن کاملNosocomial Infection in Critically Ill Patient Receiving Stress Ulcer Prophylactic Drugs
Acidic pH of stomach, which is a normal physiological barrier against bacterial overgrowth, would increase by stress ulcer prophylaxis initiation and may lead to bacterial colonization and play as a source for infection transmission to the respiratory system which results in ventilator related pneumonia in patients admitted to the Intensive Care Units (ICUs). Therefore, finding methods to ...
متن کاملHeat-and-moisture exchangers used with biweekly circuit tubing changes: effect on costs and pneumonia rates.
In 1991, heat-and-moisture exchangers were introduced with biweekly ventilator circuit tubing changes, resulting in elimination of multiple pieces of respiratory equipment and reduced labor costs. The annual savings were $157,000, totalling $1.5 million since the onset of the program. There have been no increases in rates of ventilator-associated pneumonia.
متن کاملEvidence-based clinical practice guideline for the prevention of ventilator-associated pneumonia.
BACKGROUND Ventilator-associated pneumonia (VAP) is an important patient safety issue in critically ill patients. PURPOSE To develop an evidence-based guideline for the prevention of VAP. DATA SOURCES MEDLINE, EMBASE, and the Cochrane Database of Systematic Reviews. STUDY SELECTION The authors systematically searched for relevant randomized, controlled trials and systematic reviews that i...
متن کامل