Accuracy of oscillometric blood pressure monitors for the detection of atrial fibrillation: a systematic review.
نویسندگان
چکیده
Atrial fibrillation (AF) is a significant risk factor for stroke and early detection of AF may help to identify patients in need of treatment. Automated blood pressure (BP) monitors with implemented AF or arrhythmia detection systems may be a useful tool for early diagnosis of AF. A systematic review (Medline/PubMed, Embase, Cochrane) of studies was performed to assess the accuracy of modified BP monitors (for diagnosing AF). A total of five studies (four tests in the physician's office and one at home) were selected. For the most accurate AF detection, three sequential BP measurements should be performed. Direct comparison against a 12-lead ECG showed that the highest sensitivity, 97% (95% CI: 94-100%), for detecting AF was obtained when three readings were assessed with two or three AF-positive readings. The highest specificity (97%) was obtained when performing three measurements, of which all three must be AF positive. The modified BP monitor (Microlife Corporation, Taipei, Taiwan) has high potential in improving AF screening.
منابع مشابه
Impact of atrial fibrillation on the accuracy of oscillometric blood pressure monitoring.
The introduction of automated oscillometric blood pressure monitors was the basis for today's widespread use of blood pressure self-measurement. However, in atrial fibrillation, there is a controversial debate on the use of oscillometry because there is a high variability of heart rate and stroke volume. To date, the accuracy of oscillometric blood pressure monitoring in atrial fibrillation has...
متن کاملComparison of two oscillometric blood pressure monitors in subjects with atrial fibrillation.
OBJECTIVE To compare blood pressure readings obtained with two commonly used oscillometric monitors: Omron HEM 711 AC (OM) and Welch-Allyn 52000 series NIBP/oximeter (WA) with mercury sphygmomanometers (Merc) in subjects with atrial fibrillation. METHODS We recruited 51 hemodynamically stable subjects with atrial fibrillation. Fifty four subjects in normal sinus rhythm served as controls. Sup...
متن کاملOpportunistic detection of atrial fibrillation using blood pressure monitors: a systematic review.
BACKGROUND Atrial fibrillation (AF) affects around 2% of the population and early detection is beneficial, allowing patients to begin potentially life-saving anticoagulant therapies. Blood pressure (BP) monitors may offer an opportunity to screen for AF. AIM To identify and appraise studies which report the diagnostic accuracy of automated BP monitors used for opportunistic AF detection. ME...
متن کاملAccuracy of pulse interval timing in ambulatory blood pressure measurement
Blood pressure (BP) monitors rely on pulse detection. Some blood pressure monitors use pulse timings to analyse pulse interval variability for arrhythmia screening, but this assumes that the pulse interval timings detected from BP cuffs are accurate compared with RR intervals derived from ECG. In this study we compared the accuracy of pulse intervals detected using an ambulatory blood pressure ...
متن کاملArrhythmias in Patients With Pulmonary Hypertension; A Narrative Review of the Current Literature
Incidence and prognostic relevance of supraventricular arrhythmias were evaluated in nine studies. These studies investigated patients with different forms of pulmonary hypertension. Supraventricular arrhythmias were more often found in patients with group two pulmonary hypertension. Common findings in these patients were elevated right atrial pressure and diameters and reduced tricuspid annula...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Expert review of medical devices
دوره 9 6 شماره
صفحات -
تاریخ انتشار 2012