Temperature monitoring during radiofrequency catheter ablation procedures using closed loop control. Atakr Multicenter Investigators Group.
نویسندگان
چکیده
BACKGROUND The purpose of this study was to evaluate electrode temperatures obtained using a radiofrequency ablation system that incorporates closed loop feedback control to achieve preset target electrode temperatures and to determine if closed loop temperature control results in a lower incidence of developing a coagulum. METHODS AND RESULTS Two hundred seventy patients underwent catheter ablation of atrioventricular nodal reentrant tachycardia, an accessory pathway, and/or the atrioventricular junction using an ablation system incorporating closed loop feedback control. Forty-five patients underwent catheter ablation in the power control mode in which power output was fixed, and 225 patients underwent catheter ablation in the temperature control mode. A coagulum occurred during 0.8% of radiofrequency applications in the temperature control mode versus 2.2% in the power control mode (P < .01). Electrode temperatures were within 10 degrees C of the targeted temperature during 35% of applications in the temperature control mode. Ability to achieve the targeted electrode temperature was related to the target, with radiofrequency energy applications at the atrioventricular junction resulting in the highest temperatures (70 +/- 12 degrees C) and those for ablation of the atrioventricular node the lowest (59 +/- 11 degrees C, P < .001), using a maximum of 50 W of power for both. Electrode temperatures were higher during ablation of left free wall and posteroseptal pathways than during ablation of right free wall and septal pathways. The mean and minimum temperatures associated with success were 64 +/- 12 degrees C and 44 degrees C, respectively. Overall, the electrode temperatures at successful and unsuccessful ablation sites did not differ (P > .05). CONCLUSIONS Temperature monitoring with closed loop control of power output facilitates radiofrequency catheter ablation procedures by minimizing the probability of developing a coagulum while ensuring maximum lesion formation.
منابع مشابه
Closed Loop Control
Background The purpose of this study was to evaluate electrode temperatures obtained using a radiofrequency ablation system that incorporates closed loop feedback control to achieve preset target electrode temperatures and to determine if closed loop temperature control results in a lower incidence of developing a coagulum. Methods and Results Two hundred seventy patients underwent catheter abl...
متن کاملFeatures : Cooled Tip Catheter Ablation
Just over a decade ago, the advent of tip temperature monitoring during radiofrequency (RF) energy delivery marked the beginning of a second generation of ablation catheter technology and furthered the success of catheter ablation as a therapeutic tool. RF generators were designed with a closed-loop feedback system to automatically adjust power output to avoid temperatures that would cause coag...
متن کاملMRI-conditional catheter sensor for contact force and temperature monitoring during cardiac electrophysiological procedures
Background MR-guided cardiac electrophysiological (EP) ablations has drawn increasing attention from both the MRI and EP communities, as high-contrast MR images provide images that couple anatomical information with lesion efficacy [1]. Catheter manipulation can be challenging for cardiac electrophysiologists as conventional electroanatomical maps, frequently include false space. Perforation of...
متن کاملTemperature-controlled radiofrequency catheter ablation of manifest accessory pathways.
OBJECTIVES The primary objectives of this study were to assess the feasibility of temperature-controlled radiofrequency catheter ablation of left and right sided manifest accessory pathways in patients with Wolff-Parkinson-White syndrome and to gain more insights into biophysical aspects of temperature-controlled catheter ablation in humans. BACKGROUND The electrode-tissue interface temperatu...
متن کاملAn Investigation of Brightness Changes in Ultrasound Images due to Temperature Variations in Liver Tissue during Radiofrequency Ablation
Introduction: one of the minimally invasive methods of treatmenting liver malignancies is Radiofrequency Ablation (RFA) which can be applied to primary or secondary tumors. Nevertheless, the disease recurrence is probable after RFA application partially due to the inadequate capability of temperature monitoring of the target tissue and visualizing the thermal damage. The goal of this work was t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 90 3 شماره
صفحات -
تاریخ انتشار 1994