One-minute electrochemical enzymic assay for cholesterol in biological materials.

نویسندگان

  • L C Clark
  • C A Duggan
  • T A Grooms
  • L M Hart
  • M E Moore
چکیده

In this rapid and specific micro-scale electrochemical enzymic assay for cholesterol and cholesterol esters, 10 microL of standard or sample is injected directly into a heated (50 degrees C) thermostated, oxystated cuvet containing pH 7.25 buffer, cholesterol oxidase (EC 1.1.3.6), and cholesterol esterase (EC 3.1.1.13). The cholesterol esters are hydrolyzed by the esterase, and the cholesterol is simultaneously oxidized by the oxidase. The hydrogen peroxide produced from oxidation of the unesterified cholesterol is measured by a polarographic anode covered with an acetate/polycarbonate membrane. The membrane allows hydrogen peroxide to diffuse to the platinum anode, where it is oxidized, but prevents the diffusion of ascorbic acid, uric acid, and bilirubin to the electroactive surface. Turbidity does not interfere. The correlation (r) between results by our method and the Abell-Kendall method for 105 samples of serum was 0.9994 and for 105 samples of plasma was 0.9997. Our method is convenient for the analysis of high-density lipoprotein cholesterol in plasma and serum supernates and in many kinds of tissue homogenates. Its limitations are also described.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of incomplete cholesteryl ester hydrolysis on enzymic measurements of cholesterol.

Esterolytic activity of three enzymic cholesterol reagents was evaluated with use of human serum-based reference materials. Primary cholesterol standards were used to calibrate the enzymic methods, and incomplete cholesteryl ester hydrolysis was measured as the bias between the enzymic cholesterol values and corresponding reference values. The average biases observed with eight reference specim...

متن کامل

Enzymic assay of plasma cholesterol: a comparison of analytical variations found using the Greiner GSA II and the Technicon SMA 12/60 and SMA II.

Cholesterol was assayed on the Greiner GSA II and the Technicon SMA 12/60 and SMA II autoanalyzers, with Allain's entirely enzymic method (Allain et al. (1974), Clin. Chem. 20, 470--475). The coefficients of variation in the results over a period of one month were less than 6% with the GSA II and the SMA II, but up to 9% on the SMA 12/60. Although the accuracy of the enzymic method depends on t...

متن کامل

Electrochemical assay of anti-tetanus toxoid monoclonal antibody by silver enhancement of gold nanoparticles at carbon nanotubes modified glassy carbon electrode

Tetanus is caused by the toxin secreted by Clostridium tetani. Due to the rapid infection with this bacterium, it is so important to investigate the tetanus immunity of people. Therefore, electrochemical biosensors, as one of the most effective tools in this regard, have demanded characteristics such as being fast, simple, cost-effective and portable. However, their detection sensitivity is not...

متن کامل

A water-soluble cholesterol derivative for use in augmenting serum control materials.

Cholesterol determination has been hampered by the lack of suitable means to prepare lyophilized serum control materials with an appropriate range of values. We prepared a water-soluble cholesterol derivative by first esterifying cholesterol with adipic acid and then reacting the cholesterol hemiadipate with Polyethylene Glycol 600 to form polyethoxyethanyl-cholesteryl adipate. The compound rea...

متن کامل

In vitro capacity and in vivo antioxidant potency of sedimental extract of Tinospora cordifolia in streptozotocin induced type 2 diabetes

Objective: The role of herbs against the free radicals have been put forth recently in combating many diseases. The aim of this study was to elucidate the in vitro capacity and in vivo antioxidant properties of sedimental extract of Tinospora cordifolia (SETc). Materials and Methods: SETcwas subjected to in vitro chemical analysis such as 1,1-diphenyl-2-picrylhydrazyl (DPPH), nitric oxide, hydr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 27 12  شماره 

صفحات  -

تاریخ انتشار 1981